High-resolution gas chromatographic high-resolution mass spectrometric analysis of human adipose tissue for 2,3,7,8-tetrachlorodibenzo-p-dioxin

Abstract: An analytical method is descrlbed for measuring 2,3,7,8-tetrachiorodlbenzo-p dioxin (TCDD) and other TCDD IsomersIn human tlssue samples using a highly speclfic cleanup procedure and hlgh-resolution gas chromatography/high-resoiution mass spectrometry. The 2,3,7,8-TCDD Is quantlfied by the Isotope dilutlon technique with ["C1,]2,3,7,8-TCDD as the internal standard. Other TCDD isomers are estimated by use of relative response factors. The 1 part-per-trllllon (pptr) ilmk of detectlon is adequate for determlnlng … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
23
0

Year Published

1986
1986
2014
2014

Publication Types

Select...
5
4

Relationship

1
8

Authors

Journals

citations
Cited by 82 publications
(24 citation statements)
references
References 14 publications
1
23
0
Order By: Relevance
“…The organic solvent was then concentrated by evaporation to 1.2 mL. Extracts were then purified on Florisil before being analyzed by a gas-phase chromatograph equipped with an electron capture detector (adapted from Patterson et al 1986). …”
Section: Methodsmentioning
confidence: 99%
“…The organic solvent was then concentrated by evaporation to 1.2 mL. Extracts were then purified on Florisil before being analyzed by a gas-phase chromatograph equipped with an electron capture detector (adapted from Patterson et al 1986). …”
Section: Methodsmentioning
confidence: 99%
“…The laboratory procedures we used to analyze polychlorinated dibenzo-p-dioxins (PCDDs), dibenzofurans (PCDFs), and PCBs in adipose tissue and serum have been previously described in detail (29,(32)(33)(34)(35)(36)(37) and only a briefdescription will be given here.…”
Section: Methodsmentioning
confidence: 99%
“…We spiked the adipose tissue (32,33,36) or serum (29,34,35,37) samples with carbon-13-labeled PCDDs, PCDFs, and coplanar PCBs and in a separate analysis with carbon-13-labeled nonplanar PCBs. The separate analysis eliminated a previous problem with high recoveries of carbon-13-labeled PCB-77 (29).…”
Section: Sample Cleanup and Quantificationmentioning
confidence: 99%
“…We do not report results for PCB 77 and OCDF because the relevant QA/QC procedures for these analytes were not met. Details of the procedures were first described by Patterson (Patterson et al, 1986(Patterson et al, , 1987 and modified in the current analysis as described below.…”
Section: Methodsmentioning
confidence: 99%