1993
DOI: 10.1016/0009-2614(93)89169-i
|View full text |Cite
|
Sign up to set email alerts
|

High-resolution laboratory absorption cross section of O3. Temperature effect

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

9
156
1
2

Year Published

1996
1996
2018
2018

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 212 publications
(170 citation statements)
references
References 5 publications
9
156
1
2
Order By: Relevance
“…The OMI random noise errors reported in the level 1b radiance data are used to construct the measurement error covariance matrix. Ozone cross sections are from Brion-Daumont-Malicet (BDM) (Brion et al, 1993), which was recommended for use in ozone profile retrievals from UV measurements by Liu et al (2007) and Liu et al (2013). Despite these similarities, the two algorithms have many different implementation details, including state and a priori components, radiative transfer model calculations, and radiometric and wavelength calibration treatments.…”
Section: Ozone Monitoring Instrument (Omi) and Omi Ozone Algorithmsmentioning
confidence: 99%
“…The OMI random noise errors reported in the level 1b radiance data are used to construct the measurement error covariance matrix. Ozone cross sections are from Brion-Daumont-Malicet (BDM) (Brion et al, 1993), which was recommended for use in ozone profile retrievals from UV measurements by Liu et al (2007) and Liu et al (2013). Despite these similarities, the two algorithms have many different implementation details, including state and a priori components, radiative transfer model calculations, and radiometric and wavelength calibration treatments.…”
Section: Ozone Monitoring Instrument (Omi) and Omi Ozone Algorithmsmentioning
confidence: 99%
“…Ozone retrieval requires the use of measured laboratory high-spectral-resolution absorption coefficients (Brion et al 1993(Brion et al , 1998Daumont et al 1992;Malicet et al 1995). The EPIC-measured reflectance spectra are compared with a set of radiative transfer-derived lookup tables for the EPIC filter transmission functions and for a wide range of ozone values.…”
Section: Products Epic Ozone and Lambert Equivalent Reflectivity Retmentioning
confidence: 99%
“…For this purpose we calculate the ozone absorption coefficients for the four ozone cross sections evaluated in the "ACSO" committee ("Absorption Cross Sections of Ozone") (Orphal et al, 2016). Among the available data sets there are versions of Bass and Paur (1985) cross-sections denoted as Brewer operational (Brw), IGACO quadratic coefficient (B&P), the crosssections of Daumont Brion Malicet (DBM) (Daumont et al, 1992;Brion et al, 1993;Malicet et al, 1995), and the newly recommended data set for ozone ground-based calculation by Serdyuchenco, Groshelev, Weber (SGW) (Serdyuchenko et al, 2012;Gorshelev et al, 2014;Weber et al, 2016).…”
Section: Slit Parametrizationmentioning
confidence: 99%