1995
DOI: 10.1007/bf00868738
|View full text |Cite
|
Sign up to set email alerts
|

High-resolution light microscopy for interpretation of renal biopsies

Abstract: Routine transmission electron microscopy is recommended for all renal biopsies. However, most of the diagnostic lesions in renal pathology are 0.2 micron or larger, and are therefore visible by light microscopy. These lesions are difficult to evaluate in paraffin sections due to problems inherent in the method itself. Full utilization of the resolving power of the light microscope or high-resolution light microscopy is possible with resin (plastic) histotechnology. The replacement of conventional histotechnolo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
7
0

Year Published

1997
1997
2019
2019

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(8 citation statements)
references
References 38 publications
1
7
0
Order By: Relevance
“…The sections are protected, and no discoloration or scratches have been noticed after 12 yr. In these sections, lesions of 0.2 p m (about the diameter of a mitochondrium) are easily recognized in the light microscope; therefore, diagnosis is possible directly from these sections, saving unnecessary further use of TEM (12)(13)(14)(15)(16). When TEM studies are required (structures 0.2 p m or less), the samples are obtained directly from the epoxy block used for HRLM and not from a separate blind sample.…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…The sections are protected, and no discoloration or scratches have been noticed after 12 yr. In these sections, lesions of 0.2 p m (about the diameter of a mitochondrium) are easily recognized in the light microscope; therefore, diagnosis is possible directly from these sections, saving unnecessary further use of TEM (12)(13)(14)(15)(16). When TEM studies are required (structures 0.2 p m or less), the samples are obtained directly from the epoxy block used for HRLM and not from a separate blind sample.…”
Section: Discussionmentioning
confidence: 99%
“…Mincing the sample for TEM has been and probably still is necessary to obtain the best fixation for experimental material (16)(17)(18)(19). Mincing was originally introduced to facilitate fixation by osmium tetraoxide (osmic acid), an excellent but slow penetrating fixative (44).…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations