2020
DOI: 10.3389/fbioe.2020.00234
|View full text |Cite
|
Sign up to set email alerts
|

High-Sensitivity Detection of the Lung Cancer Biomarker CYFRA21-1 in Serum Samples Using a Carboxyl-MoS2 Functional Film for SPR-Based Immunosensors

Abstract: We constructed a novel surface plasmon resonance (SPR) detection assay using carboxyl-functionalized molybdenum disulfide (carboxyl-MoS 2) nanocomposites as a signal amplification sensing film for the ultrasensitive detection of the lung cancer-associated biomarker cytokeratin 19 fragment (CYFRA21-1). The experiment succeeded in MoS 2 reacted with chloroacetic acid giving carboxyl-MoS 2 as the reaction product. The additional shoulder in the C 1s and O 1s peaks of carboxyl-MoS 2 , which were increased in X-ray… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
28
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
4
3
1

Relationship

1
7

Authors

Journals

citations
Cited by 67 publications
(39 citation statements)
references
References 50 publications
(49 reference statements)
0
28
0
Order By: Relevance
“…Based on Figure 15B , biosensor selectivity also shows good results. The SPR angle shift on the CYFRA21-1 protein shows a much greater magnitude than other types of proteins (CA-199, hCG, PAPP-A, PAPP-A2, and HAS) (Chiu and Yang, 2020 ).…”
Section: Mos 2 Based Spr Biosensormentioning
confidence: 84%
See 2 more Smart Citations
“…Based on Figure 15B , biosensor selectivity also shows good results. The SPR angle shift on the CYFRA21-1 protein shows a much greater magnitude than other types of proteins (CA-199, hCG, PAPP-A, PAPP-A2, and HAS) (Chiu and Yang, 2020 ).…”
Section: Mos 2 Based Spr Biosensormentioning
confidence: 84%
“…Chiu and Yang ( 2020 ) used a single-layer MoS 2 -COOH for signal amplification to detect lung cancer associated with the cytokeratin 19 fragment biomarker (CYFRA21-1) using an SPR-based biosensor. To detect CYFRA21-1, MoS 2 /COOH-based SPR chip was functionalized using lung cancer antibodies (anti-CYFRA21-1, TROMA-III).…”
Section: Mos 2 Based Spr Biosensormentioning
confidence: 99%
See 1 more Smart Citation
“…This nanomaterial has been recently used in several SPR-based approaches [ 104 ]. SPR immunosensors were developed for the detection of biomarker proteins using both direct immobilization [ 105 ], coupling via terminal -COOH groups introduced through sulphur vacancies [ 106 ], and the decoration of nanomaterial deposited in the form of nanoflowers on the surface of the SPR transducer with gold nanoparticles [ 107 ].…”
Section: Functional Surfaces and Non-oriented Ab Immobilization Strategies For Spr Immunosensingmentioning
confidence: 99%
“…Several examples involving the detection of alpha fetoprotein hepatocellular cancer biomarker and the CA125/MUC16 ovarian tumor circulating biomarker have employed SERS, SPR and SPRi applications without exploiting any other antifouling strategy besides the dilution of serum samples [75][76][77]. In this line, an SPR-based immunosensor makes use of carboxyl-modified MoS 2 composites to detect the lung-cancer-associated biomarker cytokeratin 19 fragment (CYFRA21-1) in spiked diluted samples [78]. The fouling effect was measured by evaluating SPR angular shifts for various serum dilutions.…”
Section: Other Cancer-related Proteinsmentioning
confidence: 99%