2012
DOI: 10.1016/j.jchromb.2012.07.005
|View full text |Cite
|
Sign up to set email alerts
|

High-throughput assay for simultaneous quantification of the plasma concentrations of morphine, fentanyl, midazolam and their major metabolites using automated SPE coupled to LC–MS/MS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
25
0

Year Published

2013
2013
2019
2019

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 52 publications
(26 citation statements)
references
References 25 publications
1
25
0
Order By: Relevance
“…There were some methods reported for detecting morphine or its metabolites. Ghassabian et al simultaneously analyzed morphine, fentanyl, midazolam, and their major metabolites in human blood using LC-MS/MS [25], with the linear concentration ranges from 3.5 to 700 ng/mL for morphine and its metabolites. Clavijo et al determined morphine and its active metabolites M3G and M6G in human plasma and dried blood spots with a linear range of 0.25-100 ng/mL for morphine and M3G, and 1ß100 ng/mL for M6G [26].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…There were some methods reported for detecting morphine or its metabolites. Ghassabian et al simultaneously analyzed morphine, fentanyl, midazolam, and their major metabolites in human blood using LC-MS/MS [25], with the linear concentration ranges from 3.5 to 700 ng/mL for morphine and its metabolites. Clavijo et al determined morphine and its active metabolites M3G and M6G in human plasma and dried blood spots with a linear range of 0.25-100 ng/mL for morphine and M3G, and 1ß100 ng/mL for M6G [26].…”
Section: Discussionmentioning
confidence: 99%
“…One cycle of analysis of four compounds including positive ion and anion mode was 13 min; the retention time for morphine and its metabolites determination is only 1.8 min under positive ion mode. The mass spectrometer was modulated to own the anion and positive ion mode by using AJS ESI ion source under the following general conditions: capillary voltage: 5 kV for gemfibrozil and M6G-d3 (IS), 25 kV for M3G and M6G, and 30 kV for morphine; nebulization pressure: 45 psi; temperature of drying gas: 350ЊC; drying gas flow: 8 L/min; sheath gas temperature: 350ЊC; sheath gas flow: 11 L/min; cell accelerator voltage: 3 V for gemfibrozil and 4 V for morphine, M3G, M6G, and M6G-d3 (IS); collision energy: 5 eV for gemfibrozil and M6G-d3 (IS), 25 …”
Section: Uhplc-ms/ms Methodsmentioning
confidence: 99%
“…Evidence-based practices such as use of sedation protocols [52], allowing lighter sedation with daily interruptions [52][53][54] and minimizing administration of paralytic agents, have all been shown to reduce morbidity in critically ill patients. However, these practices may not always be practical in a critically ill patient on ECLS.…”
Section: Sedatives and Analgesicsmentioning
confidence: 99%
“…This research will characterise the PK of 18 important drugs (Chapter 4) used during ECMO utilising validated ex vivo and large animal models of ECMO 52,53 ,efficient drug and metabolite assays 54 and a multi-national population PK collaboration 55 . This mechanistic data can be translated into clinical practice rapidly, facilitating optimal pharmacotherapy, minimizing the risk of therapeutic failure and the rise of antibiotic resistance from sub-therapeutic concentrations.…”
Section: Objectivesmentioning
confidence: 99%
See 1 more Smart Citation