2019
DOI: 10.2967/jnumed.119.228692
|View full text |Cite
|
Sign up to set email alerts
|

High-Throughput PET/CT Imaging Using a Multiple-Mouse Imaging System

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
36
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 34 publications
(38 citation statements)
references
References 13 publications
2
36
0
Order By: Relevance
“…Similar behavior has been observed and reported on by Aide et al [32] and Siepel et al [9], who attributed this to the combined effect of 'over-estimation of scatter correction plus the nonnegativity constraint in the image reconstruction'. Furthermore, Greenwood et al [12] showed that the smaller, 1 mm diameter rod was not discernible when scanning four phantoms simultaneously, which stands by our observations that RC diminishes as more sources of activity are introduced into the FOV.…”
Section: Recovery Coefficientsmentioning
confidence: 51%
See 2 more Smart Citations
“…Similar behavior has been observed and reported on by Aide et al [32] and Siepel et al [9], who attributed this to the combined effect of 'over-estimation of scatter correction plus the nonnegativity constraint in the image reconstruction'. Furthermore, Greenwood et al [12] showed that the smaller, 1 mm diameter rod was not discernible when scanning four phantoms simultaneously, which stands by our observations that RC diminishes as more sources of activity are introduced into the FOV.…”
Section: Recovery Coefficientsmentioning
confidence: 51%
“…Reilhac et al [11] reported a higher increase of 43% in the %STD of the uniformity when scanning a Derenzo phantom alongside a NEMA IQ phantom. Finally, Greenwood et al [12] reported a decrease in uniformity (an increase of 55% in %STD) when assessing four phantoms simultaneously vs the single centered case. It may be expected to see such a significant increase in %STD when there are four sources of activity present, which was not assessed in our study.…”
Section: Uniformitymentioning
confidence: 99%
See 1 more Smart Citation
“…We encourage the reader to refer elsewhere [1][2][3] for a detailed discussion of resolution and image quality obtainable with standard radionuclides (e.g. 18 F, 11 C) in simultaneous multi-animal imaging.…”
Section: Discussionmentioning
confidence: 99%
“…One solution to this has been the use of 3D printed beds, referred to as hotel imaging. This allows the researcher to image 2-4 animals at a time (Greenwood et al 2019;Dazai et al 2011). Thanks to their technical and clinical experience, NMTs and radiographers can easily position themselves in this kind of structure.…”
Section: What Is Preclinical Imaging?mentioning
confidence: 99%