2009
DOI: 10.1016/j.jasms.2008.10.011
|View full text |Cite
|
Sign up to set email alerts
|

High-throughput quantitative analysis by desorption electrospray ionization mass spectrometry

Abstract: A newly developed high-throughput desorption electrospray ionization (DESI) source was characterized in terms of its performance in quantitative analysis. A 96-sample array, containing pharmaceuticals in various matrices, was analyzed in a single run with a total analysis time of 3 min. These solution-phase samples were examined from a hydrophobic PTFE ink printed on glass. The quantitative accuracy, precision, and limit of detection (LOD) were characterized. Chemical background-free samples of propranolol (PR… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
69
0

Year Published

2009
2009
2020
2020

Publication Types

Select...
6
4

Relationship

3
7

Authors

Journals

citations
Cited by 99 publications
(71 citation statements)
references
References 22 publications
2
69
0
Order By: Relevance
“…The home-built DESI ion source is similar to the OmniSpray source from Prosolia Inc. (Indianapolis, IN, USA), configured as described previously [91]. A sprayer-to-surface distance of 2 mm, a sprayer-to-inlet distance of 2.5 mm, an incident angle to the horizontal of 52°and a collection angle of 10°were used.…”
Section: Mass Spectrometrymentioning
confidence: 99%
“…The home-built DESI ion source is similar to the OmniSpray source from Prosolia Inc. (Indianapolis, IN, USA), configured as described previously [91]. A sprayer-to-surface distance of 2 mm, a sprayer-to-inlet distance of 2.5 mm, an incident angle to the horizontal of 52°and a collection angle of 10°were used.…”
Section: Mass Spectrometrymentioning
confidence: 99%
“…DESI-MS was performed on a ThermoFinnigan LTQ mass spectrometer (ThermoScientific, San Jose, CA) coupled to a custom built, 2-D automated DESI source as described elsewhere [27]. The solvent was delivered through a fused silica inner capillary (i.…”
Section: Desorption Electrospray Ionization Mass Spectrometry (Desi-ms)mentioning
confidence: 99%
“…The correlation coefficient (R 2 ) resulting from these analyses was 0.9964, and relative standard deviations for all calibration points ranged from 6% to 13%, showing decent precision and linearity for the entire quantitation experiment. Of note, the precision and linearity using Method 2 is comparable to quantitative DESI-MS analyses reported that utilize internal standards and automated positioning systems [40]. The linear dynamic range (LDR) for quantitation of citalopram was approaching three orders of magnitude without utilizing software-controlled automatic gain control (AGC).…”
Section: Quantitation and Optimization Of Sample Flow Ratementioning
confidence: 90%