1967
DOI: 10.1001/archsurg.1967.01330120115022
|View full text |Cite
|
Sign up to set email alerts
|

Higher Homologous Cyanoacrylate Tissue Adhesives in Surgery of Internal Organs

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
14
0

Year Published

1968
1968
2012
2012

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 41 publications
(14 citation statements)
references
References 3 publications
0
14
0
Order By: Relevance
“…The fibrin glue used in the present study (Tissucol®, Immuno AG, Viena, Austria) was the same one used by Maragh et al 32 . Many authors [5][6][7]16,18,22,30,34,42,43 have analyzed new anastomosis alternatives in order to optimize nerve regeneration. The main options include the use of artificial nerve conduction means, CO 2 laser and tissue adhesive or glue.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The fibrin glue used in the present study (Tissucol®, Immuno AG, Viena, Austria) was the same one used by Maragh et al 32 . Many authors [5][6][7]16,18,22,30,34,42,43 have analyzed new anastomosis alternatives in order to optimize nerve regeneration. The main options include the use of artificial nerve conduction means, CO 2 laser and tissue adhesive or glue.…”
Section: Discussionmentioning
confidence: 99%
“…Fibrin glue is a plasma-derived biologic concentrate of topical use, of which mechanism of action is similar to the last stage of the physiological coagulation (fibrinogen formation). The clot constituted by the glue is a physiologic component found in tissue repair, and this makes it different from other types of glue such as the cyanoacrylates, which bear high fibrin formation and is very difficult to use in moist tissue [17][18][19][20][21][22][23][24] . The fibrin glue Tissucol® (Immuno AG, Viena, Austria) commercially presents itself in two components, fibrinogen and the catalyst that, mixed by means of the Duploject® system (Immuno AG, Viena, Austria), solidify and form a plasmatic clog.…”
Section: Introductionmentioning
confidence: 99%
“…Thus, a longer observation period will be necessary in order to determine the time taken for the adhesive and its action on tissues to be eliminated. It has been recognized that esters with greater numbers of carbon atoms degrade slowly, and some authors have suggested that complete removal of the adhesive may never be attained (6,7,15,17,20,26) .…”
Section: Distal With Adhesivementioning
confidence: 99%
“…Cyanoacrylates are a group of fast-polymerization adhesives that started to be used in surgery in the 1960s (5) . These would make it possible to use this method, since they are absorbable, biocompatible, easy to use, cost--cost, sterilizable in ethylene oxide and radiotransparent, and have the property of adhering to wet surfaces (6) .…”
Section: Introductionmentioning
confidence: 99%
“…The cyanoacrylate monomers, especially methyl, have been used in both experimental (Healey, 1962) and clinical surgery (Vasko, 1965) to bind together moist living tissues, for example to seal wounds of the kidney and spleen and also to reinforce suture anastomoses. The recently introduced isobutyl cyanoacrylate (Matsumoto, 1967) is less toxic than the lower homologues and its experimental use as a tissue adhesive has recently been reported (Hale & Ellis, 1968).…”
mentioning
confidence: 99%