2011
DOI: 10.1007/s10334-011-0275-6
|View full text |Cite
|
Sign up to set email alerts
|

Highly accelerated PSF-mapping for EPI distortion correction with improved fidelity

Abstract: The proposed EPI-PSF-based distortion correction improves correction of EPI and accelerates PSF reference data acquisition and computation.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
77
0

Year Published

2015
2015
2019
2019

Publication Types

Select...
8

Relationship

6
2

Authors

Journals

citations
Cited by 58 publications
(79 citation statements)
references
References 16 publications
2
77
0
Order By: Relevance
“…Even though there may be no SAR issues related to measuring the corresponding distortion information using both the conventional field mapping (Jezzard and Balaban, 1995) and the original PSF mapping methods (Zaitsev et al, 2004), there is still a limitation in reliably correcting for severe distortions, as previously reported in studies conducted at 7T (Chung et al, 2011; In, 2012). In contrast, the correction fidelity of the proposed approach was well demonstrated in previous studies (In and Speck, 2012; In et al, 2015) and in this study. Therefore, the proposed approach would be a viable method for considering both SAR concerns and the correction fidelity in performing DBS-fMRI studies.…”
Section: Discussionsupporting
confidence: 88%
See 2 more Smart Citations
“…Even though there may be no SAR issues related to measuring the corresponding distortion information using both the conventional field mapping (Jezzard and Balaban, 1995) and the original PSF mapping methods (Zaitsev et al, 2004), there is still a limitation in reliably correcting for severe distortions, as previously reported in studies conducted at 7T (Chung et al, 2011; In, 2012). In contrast, the correction fidelity of the proposed approach was well demonstrated in previous studies (In and Speck, 2012; In et al, 2015) and in this study. Therefore, the proposed approach would be a viable method for considering both SAR concerns and the correction fidelity in performing DBS-fMRI studies.…”
Section: Discussionsupporting
confidence: 88%
“…Because an additional PSF- (or spin-warp) PE is added to the conventional 2D-EPI sequence, the PSF mapping sequence acquires 3D k -space data including a readout ( x ) and two PE, PSF-PE ( s ) and EPI-PE ( y ), dimensions, respectively suffering from negligible, no, and strong geometric distortions (Chung et al, 2011; In and Speck, 2012). The spin-warp PE is wrapped around the EPI in a conventional manner and this dimension ( s ) is distortion-free.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Thus, using a fast pre-scan for acquiring low-res sensitivity maps prior to imaging [13, 35] may be possible. Second, although several techniques for dynamic characterization of the B 0 field [44, 45] have been developed, they require additional scan time and assume that the subject remains still for each measurement step. For stronger motion, the distortion caused by B 0 field inhomogeneity has been considered for single-shot EPI time series where each acquisition can provide a field map [19, 46].…”
Section: Discussionmentioning
confidence: 99%
“…?_bold.nii.gzraw fMRI BOLD images.*rec-dico_run-? ?_bold.nii.gzDistortion corrected BOLD images [11].*motion_physio.tsv.gzWhitespace-delimited 6-column text file with motion estimates with translation along X, Y, Z axes in mm and rotation around X, Y, Z axes in deg. It contains one row per fMRI dynamic for each acquisition run.*_events.tsvText files, one for each acquisition run, with 4-columns.…”
Section: Datamentioning
confidence: 99%