2022
DOI: 10.1016/j.ijbiomac.2022.02.147
|View full text |Cite
|
Sign up to set email alerts
|

Highly efficient and selective modification of lignin towards optically designable and multifunctional lignocellulose nanopaper for green light-management applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
6
3

Relationship

3
6

Authors

Journals

citations
Cited by 22 publications
(12 citation statements)
references
References 78 publications
0
12
0
Order By: Relevance
“…The pore structures and specific surface areas of the RMCRs were determined by using adsorption-desorption experiments, as shown in Figure 1a. The RMCRs' isothermal curves also showed type II curves with well-defined H1 hysteresis-type loops, thus inferring cylindrical pores with a uniform macroporous structure [17]. The pore structures of the RMCRs had an average pore diameter of 42.40 nm (Figure 1b), Brunauer-Emmett-Teller (BET) surface area of 10.24 m 2 •g −1 , and cumulative pore volume of 22.20 mm 3 •g −1 .…”
Section: N2 Adsorption-desorption Isotherm Analysismentioning
confidence: 94%
“…The pore structures and specific surface areas of the RMCRs were determined by using adsorption-desorption experiments, as shown in Figure 1a. The RMCRs' isothermal curves also showed type II curves with well-defined H1 hysteresis-type loops, thus inferring cylindrical pores with a uniform macroporous structure [17]. The pore structures of the RMCRs had an average pore diameter of 42.40 nm (Figure 1b), Brunauer-Emmett-Teller (BET) surface area of 10.24 m 2 •g −1 , and cumulative pore volume of 22.20 mm 3 •g −1 .…”
Section: N2 Adsorption-desorption Isotherm Analysismentioning
confidence: 94%
“…The specific surface area and pore size of the samples were measured by the specific surface area and pore size analyzer (ASAP2460, Micromeritics, Georgia, USA). Nitrogen adsorption–desorption was measured at 90 °C for 12h under nitrogen protection [ 41 ].…”
Section: Methodsmentioning
confidence: 99%
“…Fourier transform infrared (FT-IR, MAGNA-IR550, Thermo Fisher Scientific, Waltham, MA, USA) spectra of membranes were measured with an infrared spectrometer with a wavenumber range of 4000-400 cm −1 . The thermogravimetric analysis (TGA) and differential thermal analysis (DTA) studies were performed using a thermal gravimetric analyzer (STA449F3, Netzsch-Gerätebau GmbH, Selb, Germany) [47]. The temperature was increased from 25 to 700 • C under a nitrogen atmosphere with a heating rate of 10 • C min −1 .…”
Section: Characterizationmentioning
confidence: 99%