2020
DOI: 10.1016/j.microc.2019.104357
|View full text |Cite
|
Sign up to set email alerts
|

Highly electrochemical performance of Ni-ZIF-8/ N S-CNTs/CS composite for simultaneous determination of dopamine, uric acid and L-tryptophan

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
22
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 59 publications
(23 citation statements)
references
References 53 publications
1
22
0
Order By: Relevance
“…This was done using the 3δ and 10δ notations. The limit of detection and limit of quantification were found to be 2.1 × 10 −6 and 5.5 × 10 −6 M, respectively, for ascorbic acid and 1.65 × 10 −6 and 5.5 × 10 −6 M for tryptophan when the two analytes coexist comparable to reported values (Filik et al, 2016;Yao et al, 2020). These values have practical significance since they closely relate to physiological concentrations which lie in the range 28-99 mM for ascorbic acid (Hagel et al, 2018), and up to 95% of tryptophan is taken up by the kynurenine pathway (Kałużna-Czaplińska et al, 2019).…”
Section: Quantification Of Tryptophan and Ascorbic Acidsupporting
confidence: 80%
“…This was done using the 3δ and 10δ notations. The limit of detection and limit of quantification were found to be 2.1 × 10 −6 and 5.5 × 10 −6 M, respectively, for ascorbic acid and 1.65 × 10 −6 and 5.5 × 10 −6 M for tryptophan when the two analytes coexist comparable to reported values (Filik et al, 2016;Yao et al, 2020). These values have practical significance since they closely relate to physiological concentrations which lie in the range 28-99 mM for ascorbic acid (Hagel et al, 2018), and up to 95% of tryptophan is taken up by the kynurenine pathway (Kałużna-Czaplińska et al, 2019).…”
Section: Quantification Of Tryptophan and Ascorbic Acidsupporting
confidence: 80%
“…Additionally, PXRD has proved the structural integrities of the frameworks. Hence, it has been applied in distinguishing the phase structures and structural integrities of the as-prepared samples [80,81].…”
Section: Powder X-ray Diffraction (Pxrd)mentioning
confidence: 99%
“…Based on the size of the MOF crystals, it is possible to use optical microscopy for obtaining valuable data on its morphology and size. SEM has been also used to examine the shape and size of ZIF particles [81,84].…”
Section: Field Emission Scanning Electron Microscopy (Fesem)mentioning
confidence: 99%
“…On the other hand, the resolution of aromatic amine isomers was not satisfactory for the LC method. There were very few reports of the separation of the three isomers 2-ABP, 3-ABP, and 4-ABP. , Schubert et al reported that the positional isomers 3-ABP and 4-ABP could not be separated at all . Regarding the fact that positional isomers usually possess a similar chemical structure and character, the discrimination and identification of the three positional isomers are a challenge and have a great significance for chemical and bioscience.…”
Section: Introductionmentioning
confidence: 99%