2011
DOI: 10.1016/j.bios.2011.02.044
|View full text |Cite
|
Sign up to set email alerts
|

Highly stable and sensitive glucose biosensor based on covalently assembled high density Au nanostructures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
28
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 74 publications
(28 citation statements)
references
References 49 publications
0
28
0
Order By: Relevance
“…This phenomenon is termed as localized surface plasmon resonance [4,5]. Among the various noble metal NPs, Au NPs have a wide range of applications such as catalysis, molecular detection, and medicine because of their excellent chemical stability [6][7][8].…”
Section: Introductionmentioning
confidence: 99%
“…This phenomenon is termed as localized surface plasmon resonance [4,5]. Among the various noble metal NPs, Au NPs have a wide range of applications such as catalysis, molecular detection, and medicine because of their excellent chemical stability [6][7][8].…”
Section: Introductionmentioning
confidence: 99%
“…Third, GOD was self-assembled on PPy-RGO-AuNPs/GCE surface mainly via the interaction between AuNPs and GOD to obtain the PPy-RGO-(AuNPs-GOD) 1 /GCE electrode. It has been reported that AuNPs can bind strongly to the biomolecule surface through covalent bonds with the functional groups such as –NH 2 , SH, and –CN, and it can provide a suitable microenvironment for biomolecules, such as enzyme and nucleic acids [11,36]. Finally, different layers of AuNPs-GOD multilayer films were built up on the PPy-RGO/GCE surface by repeating the process of electrodeposition of AuNPs and self-assembly of GOD to obtain PPy-RGO-(AuNPs-GOD) n /GCE electrode.…”
Section: Resultsmentioning
confidence: 99%
“…Its sensitivity was 63.8 mA M -1 cm -2 , which was much higher than that of glucose biosensor based on ZrO2/chitosan/GOx (22.3 mA M -1 cm -2 ), 27 Graphene/AuNPs/ GOx/Chitosan (17.5 mA M -1 cm -2 ), 28 and GOx/(AuNPs/ MWCNT) 5 (19.3 mA M -1 cm -2 ). 29 This analytical performance of the proposed CNS/SA/GOx electrode was also compared with those reported in the literature for the GOx-based biosensors using other matrixes ( Table 1). The high sensitivity and low detection limit of the CNS/SA/GOx sensor may be attributed to the combined merits of CNS and SA, such as good biocompatible and hydrophilic microenvironments, high film-forming ability and adsorption ability.…”
Section: Amperometric Biosensor Detection Of Glucosementioning
confidence: 85%