2011
DOI: 10.21236/ada538244
|View full text |Cite
|
Sign up to set email alerts
|

HITRAN/HITEMP Spectral Databases and Uncertainty Propagation by Means of Monte Carlo Simulation with Application to Tunable Diode Laser Absorption Diagnostics

Abstract: Reviewed by: CARRIE REINHOLTZ Project Manager Technology Branch (TTSY), USAF Approved by:SCOTT WALTERMIRE Technical Director Technology Branch (TTSY), USAF REPORT DOCUMENTATION PAGE Form Approved OMB No. 0704-0188The public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send commen… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 31 publications
0
3
0
Order By: Relevance
“…) n P = 2γP + 2 ∑ i γ i P i (6) among them, γ and P are the pressure broadening coefficient and pressure of the gas to be measured, n is the temperature coefficient, and γ ii and P i represent the pressure broadening coefficient and pressure of the colliding gas, respectively. In order to improve the accuracy and sensitivity of the detection, this paper adopts the wavelength modulation spectroscopy (WMS) technique [19,20].…”
Section: Gas Samplementioning
confidence: 99%
See 1 more Smart Citation
“…) n P = 2γP + 2 ∑ i γ i P i (6) among them, γ and P are the pressure broadening coefficient and pressure of the gas to be measured, n is the temperature coefficient, and γ ii and P i represent the pressure broadening coefficient and pressure of the colliding gas, respectively. In order to improve the accuracy and sensitivity of the detection, this paper adopts the wavelength modulation spectroscopy (WMS) technique [19,20].…”
Section: Gas Samplementioning
confidence: 99%
“…In order to study the effects of temperature changes on TDLAS gas measurements, many scholars utilize spectral parameters from the High-Resolution Transmission Molecular Absorption Database (HITRAN) [6]. For example, the intensity of the spectral line, the absorption coefficient, and the absorption linear parameters have been studied.…”
Section: Introductionmentioning
confidence: 99%
“…Numerous studies have been performed to investigate the influence of temperature variation on TDLAS measurement. Many of them used spectroscopic parameters such as line intensity [20] from databases like HITRAN (High Resolution Transmission) or HITEMP (High Temperature Molecular Spectroscopic). Nevertheless, these databases, which mainly derive from theoretical calculation, may have some uncertainty while applied in high-temperature measurement.…”
Section: Introductionmentioning
confidence: 99%