1982
DOI: 10.1007/bf02798321
|View full text |Cite
|
Sign up to set email alerts
|

Homogeneous immunoassays

Abstract: Luminescent [6][7][8]. Enzyme channeling immunoassays are applicable to both small and large molecules but have limited sensitivity because of their susceptibility to matrix effects. In these assays, an immune reaction brings two enzymes into proximity on a surface; at that surface, one enzyme produces a product that serves as a chromogenic substrate for the second enzyme [9]. The product reaches higher concentrations near the surface than in the bulk solution, which leads to an increase in the rate of reactio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

1986
1986
2024
2024

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(3 citation statements)
references
References 37 publications
0
3
0
Order By: Relevance
“…Immunoassays have been divided into homogeneous assays, which require no physical separation (Rubenstein et al, 1972;Boguslaski and Li, 1982;Looney, 1984), and heterogeneous assays, which require physical separation in order to determine degree of displacement or binding by monitoring the bound/free ratio of labeled ligand or receptor (see Chapter 1). An overview of separation methods most commonly employed in heterogeneous immunoassays is presented in Table IV. A. Liquid-Phase Methods Separation of free and bound labeled ligand or receptor was accomplished in many early immunoassays by differential adsorption of the labeled reagent to a solid material.…”
Section: Separation Techniquesmentioning
confidence: 99%
“…Immunoassays have been divided into homogeneous assays, which require no physical separation (Rubenstein et al, 1972;Boguslaski and Li, 1982;Looney, 1984), and heterogeneous assays, which require physical separation in order to determine degree of displacement or binding by monitoring the bound/free ratio of labeled ligand or receptor (see Chapter 1). An overview of separation methods most commonly employed in heterogeneous immunoassays is presented in Table IV. A. Liquid-Phase Methods Separation of free and bound labeled ligand or receptor was accomplished in many early immunoassays by differential adsorption of the labeled reagent to a solid material.…”
Section: Separation Techniquesmentioning
confidence: 99%
“…Such labels have included enzymes, co-enzymes, fluorescent dyes, fluorogenic substrates, chemiluminescence precursors, stable free radicals, a luminol reactive heme-containing compound, bacteriophages and metal atoms. This subject has been reviewed by Oellerich (114), Schall and Tenoso (134,135) Chang (29), Visor and Schulman (158), and Boguslaski and Li (23).…”
Section: Immunoassays Utilizing Enzymesmentioning
confidence: 99%
“…However, the use of enzymes as tracer in immunoassays was first introduced by van Weeman and Schuurs (154) and Engvall and Perlmann (43). Since that time, a number of different concepts have been introduced and reviews dealing with methodology principles, characteristics, application, automation and semi-automation (23,134,136,139,159,162), application in diagnostic medicine (160), microbiology (42) and clinical chemistry (114) have been published. In addition, studies on the adsorptive characteristics (immobilization) of antigens on plastics for use in EIA (27,87,141), the optimization of EIA (25,48,153,167), factors affecting their sensitivity (73,74,132), and interpretation of data (56,127) have been reported.…”
Section: Immunoassays Utilizing Enzymesmentioning
confidence: 99%