"Hot" for warm water cooling

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(7 citation statements)
references
References 0 publications
0
7
0
Order By: Relevance
“…As a result, the temperature in the rack circuit increases until it goes above 55 • C/131 • F and the chiller turns on. 2 What happens then depends on the temperature dependence of the function P max d (T ) = P max c (T )/COP(T ), which is the maximum power that can be removed from the driving circuit of the chiller. This function depends on the parameters of the chiller.…”
Section: Water Inletmentioning
confidence: 99%
See 1 more Smart Citation
“…As a result, the temperature in the rack circuit increases until it goes above 55 • C/131 • F and the chiller turns on. 2 What happens then depends on the temperature dependence of the function P max d (T ) = P max c (T )/COP(T ), which is the maximum power that can be removed from the driving circuit of the chiller. This function depends on the parameters of the chiller.…”
Section: Water Inletmentioning
confidence: 99%
“…A discussion of various aspects of liquid cooling with focus on high coolant temperatures can be found in Refs. [2,3]. For the following discussion, we assume that the cooling medium is water and define what we mean by "warm water" and "hot water".…”
Section: Introductionmentioning
confidence: 99%
“…For each of these one can consider keeping the primary cooling fluid temperature either close to room temperature or significantly above room temperature (warm water cooling [289]). When the primary cooling fluid is significantly above environmental conditions, then seasonal temperature changes have negligible effects on efficiency of conversion of heat for other uses and the generated heat can be more effectively recycled.…”
Section: Overview Of Data Center Cooling Methodologiesmentioning
confidence: 99%
“…Thus, in green data centres aimed for high-performance computing, it is advantageous to use some form of direct liquid cooling instead of pure air cooling, since this would enhance the opportunity to reuse the waste heat more effectively and, simultaneously, increase the usage of the CPU turbo mode (Gepner et al, 2010). The thermal capacity of liquids is noticeably larger than that of air -air 1.00 kJ/(K·kg) and water 4.18 kJ/(K·kg), for instance -and after the heat energy has been transferred to water, it can be removed from the data centre efficiently (Coles et al, 2011). Moreover, for green data centres, water is usually the preferred liquid, because it is non-toxic, as well as more available and less expensive than other types of liquid.…”
Section: Solutions For Liquid Coolingmentioning
confidence: 99%