2012
DOI: 10.1016/j.applthermaleng.2012.01.058
|View full text |Cite
|
Sign up to set email alerts
|

Hourly performance prediction of ammonia–water solar absorption refrigeration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
14
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 48 publications
(14 citation statements)
references
References 35 publications
0
14
0
Order By: Relevance
“…The remaining solution (8) flows back to the absorber and, thus, completes the cycle. In order to improve system performance, the solution heat exchanger is included in the cycle [12][13][14][15][16][17][18][19][20]. Due to high efficiency at high temperature, the evacuated tube solar collector type has been chosen as it can provide good performance at the high temperature required by the absorption system as stated by Assilzadeh et al [21].…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The remaining solution (8) flows back to the absorber and, thus, completes the cycle. In order to improve system performance, the solution heat exchanger is included in the cycle [12][13][14][15][16][17][18][19][20]. Due to high efficiency at high temperature, the evacuated tube solar collector type has been chosen as it can provide good performance at the high temperature required by the absorption system as stated by Assilzadeh et al [21].…”
Section: Methodsmentioning
confidence: 99%
“…It is assumed for the calculation that the evacuated solar collector surface is placed with tilted angle of 23 0 degree and oriented to the south direction. The solar radiation production on collector surface area and the heat output from solar collectors can be determined using the Hottel-Whillier equation [12,30,31]:…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…In addition, they do not contribute emissions to the ozone depletion or to the global warming. Although absorption refrigeration systems seem to provide many advantages, their COP is too low and initial investment cost is very high [4,8]. The most important parameter is the performance of solar collectors in the design of absorption cooling machine.…”
Section: Introductionmentioning
confidence: 99%
“…Considering that comfort cooling demand increases with the intensity of solar radiation. For this reason, solar air-conditioning has been considered as a logical solution [4].…”
Section: Introductionmentioning
confidence: 99%