How Drill-Generated Acoustic Trauma effects Hearing Functions in an Ear Surgery?

Abstract: Objective: In otology, a wide variety of devices are used that have significant noise output, both operated ear and the patient. We aimed to determine hearing damages due to drill-generated acoustic trauma in ear surgery. We want to find how degree drill-generated acoustic trauma is responsible from sensorineural hearing loss in ear surgery. Materials and methods:We designed a retrospective study about 100 patients who underwent radical or modiphied radical mastoidectomy and tympanoplasty. The audiometric test… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
8
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(9 citation statements)
references
References 11 publications
1
8
0
Order By: Relevance
“…1 and 6.6 dB). 9 This is similar to our study where there is a decline in 3 dB compared to preoperative status in lower frequencies (Figure 1).…”
Section: Discussionsupporting
confidence: 91%
See 2 more Smart Citations
“…1 and 6.6 dB). 9 This is similar to our study where there is a decline in 3 dB compared to preoperative status in lower frequencies (Figure 1).…”
Section: Discussionsupporting
confidence: 91%
“…5,6 The intensity of noise generated depends on various parameters including rotation speed, type of burr, burr size, and site of drilling (a solid area or aerated area).9 Mastoid drilling with larger size (6 mm cutting) burr generates an intensity of 88 to 108 dB, whereas there is further noise reduction with decreased burr size and the maximum reduction is seen with the small 2 mm burr (up to 16 dB). 9 The sound pressure level produced by the cutting burr is more than the levels of the diamond burr, so, in vital structures diamond burr is advised. 10,11 High-speed drill produces a low noise level causing less damage to hair cells of the cochlea and is safer compared to the low-speed drill that generates the highest intensity sound.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…They reported that bone conduction can impaired with drill noise most at frequencies but, they showed PTA changes can be permanent. [ 16 ] Kylén and Arlinger had described that the noise trauma can account some patient in high-tone frequency after tympanoplasty. [ 17 ] As the values, different frequencies of DPOAEs and TEOAEs were significantly different preoperatively and postoperative (1 and 7 days).…”
Section: Discussionmentioning
confidence: 99%
“…19 Paksoy et al, in their study state that drill induced sensorineural hearing loss is one of the causes of hearing loss. 20 Alharbi et al, in their study state that one should avoid touching ossicular chain during ear surgery as a high focused acoustic energy is transmitted to inner ear causing damage in structure and deterioration of function. Spontaneous recovery could occur after acoustic trauma but may be incomplete with permanent scar formation in outer haircells.…”
Section: Cortmast Tplastymentioning