2015
DOI: 10.1016/j.jpurol.2014.11.020
|View full text |Cite
|
Sign up to set email alerts
|

How to decide which infant can have robotic surgery? Just do the math

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
26
0
2

Year Published

2015
2015
2022
2022

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 58 publications
(28 citation statements)
references
References 16 publications
0
26
0
2
Order By: Relevance
“…Mini‐invasive HN is even more demanding and technically difficult in young children because of their small abdomen size . The impact of the limited anatomical workspace in toddlers is still a matter of debate in the field of minimally invasive surgery . Thus, some authors reported significant functional loss of the residual moiety, and advocated for the use of an open approach in children aged <1 year .…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Mini‐invasive HN is even more demanding and technically difficult in young children because of their small abdomen size . The impact of the limited anatomical workspace in toddlers is still a matter of debate in the field of minimally invasive surgery . Thus, some authors reported significant functional loss of the residual moiety, and advocated for the use of an open approach in children aged <1 year .…”
Section: Introductionmentioning
confidence: 99%
“…8 The impact of the limited anatomical workspace in toddlers is still a matter of debate in the field of minimally invasive surgery. 9 Thus, some authors reported significant functional loss of the residual moiety, and advocated for the use of an open approach in children aged <1 year. 10 In this population, standard transperitoneal laparoscopic or retroperitoneoscopic HN approaches were recently reported to be safe and to have a low conversion rate.…”
Section: Introductionmentioning
confidence: 99%
“…Trocar placement is a crucial step in robotic-assisted surgery in order to minimize instrument collision and operative time. A recent study demonstrated that collisions are minimized if the distance between both anterior superior iliac spines is >13 cm, or if the puboxyphoid distance is >15 cm (19).…”
Section: Trocar Placementmentioning
confidence: 99%
“… [5] found that operative times, hospital stay, and postoperative outcomes were similar in children greater than or less than 15 kg, with only longer robotic set-up times for patients less than 15 kg, and Finkelstein et al. [6] found that at least a 13 cm distance between anterior superior iliac spines (for lower urinary tract procedures) and at least a 15 cm puboxyphoid (for upper urinary tract procedures) can aid in selecting infants for robotic surgery.…”
Section: Introductionmentioning
confidence: 99%