2022
DOI: 10.1016/j.jics.2022.100348
|View full text |Cite
|
Sign up to set email alerts
|

HPLC–based methods for the determination of levetiracetam in biological and pharmaceutical samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 39 publications
0
3
0
Order By: Relevance
“…The linear relation between peak current and LEV concentration is expressed in the following Eq. ( 10), I p = 0.0392C + 0.4658, R 2 = 0.9938 (10) The value of LOD and LOQ for the proposed SWSV method was evaluated by employing the following relations, LOD = , (11) LOQ = (12) Where S denotes the standard deviation of peak current values and M refers to the slope of the calibration plots. The reported values of LOD (Eq.…”
Section: Determination Of Surface Coverage (γ O ) and Diffusion Coe C...mentioning
confidence: 99%
See 1 more Smart Citation
“…The linear relation between peak current and LEV concentration is expressed in the following Eq. ( 10), I p = 0.0392C + 0.4658, R 2 = 0.9938 (10) The value of LOD and LOQ for the proposed SWSV method was evaluated by employing the following relations, LOD = , (11) LOQ = (12) Where S denotes the standard deviation of peak current values and M refers to the slope of the calibration plots. The reported values of LOD (Eq.…”
Section: Determination Of Surface Coverage (γ O ) and Diffusion Coe C...mentioning
confidence: 99%
“…Various analytical methods are reported in the literature for the quantitative and qualitative determination of LEV in pure, medicinal dosage, and tablet form including spectrophotometry [8], gas chromatography (GC) [9], high-performance liquid chromatography (HPLC) [10], liquid chromatography-mass spectrometry (LC-MS) [11], HPLC-electro spray tandem mass spectrometry (HPLC-ESI-MS) [12], spectro-uorimetry [13] and capillary electrophoresis [14].…”
Section: Introductionmentioning
confidence: 99%
“…The least square method is employed for the determination of linearity. 17 Precision Six tablets of ropinirole and levetiracetam were subjected to a dissolution test for repeatability on the same day and two different days. Different HPLC instrument (Agilent 1200 series LC system) is also used for the determination of precision.…”
Section: Specificitymentioning
confidence: 99%