2004
DOI: 10.1016/s0731-7085(03)00644-7
|View full text |Cite
|
Sign up to set email alerts
|

HPLC enantiomer separation of a chiral 1,4-dihydropyridine monocarboxylic acid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
19
0

Year Published

2008
2008
2019
2019

Publication Types

Select...
4
1
1

Relationship

3
3

Authors

Journals

citations
Cited by 34 publications
(20 citation statements)
references
References 11 publications
1
19
0
Order By: Relevance
“…The optimization gave a baseline separation of all four stereoisomers of 44 and 45 in a single run [88]. Several pharmacologically active acids have also been successfully separated, including nonsteroidal anti-inflammatory profens such as naproxen 46, ibuprofen 47, flurbiprofen 48 [58,66], planar chiral acid 49 [89], quinazolone derivatives 50 [90], and monomethyl ester of 4-(2 0 ,3 0 -dichlorophenyl)-2,6-dimethyl-1,4-dihydropyridine-3,5-dicarboxylic acid 51 -an active metabolite of the short-acting calcium antagonist clevidipine [91].…”
Section: Applicationsmentioning
confidence: 99%
“…The optimization gave a baseline separation of all four stereoisomers of 44 and 45 in a single run [88]. Several pharmacologically active acids have also been successfully separated, including nonsteroidal anti-inflammatory profens such as naproxen 46, ibuprofen 47, flurbiprofen 48 [58,66], planar chiral acid 49 [89], quinazolone derivatives 50 [90], and monomethyl ester of 4-(2 0 ,3 0 -dichlorophenyl)-2,6-dimethyl-1,4-dihydropyridine-3,5-dicarboxylic acid 51 -an active metabolite of the short-acting calcium antagonist clevidipine [91].…”
Section: Applicationsmentioning
confidence: 99%
“…7) because of the slow mass transfer in the CSP, well known for enantioselective chromatography systems with its heterogeneous adsorption sites. 26 In the present case, an improvement of the plate counts by a factor of about 1.5 could be achieved for 5-MATIDA by reducing the eluent flow rate from 1.0 to 0.25 ml/min. For 4-CPHE enantiomers the efficiency gain was even more noteworthy, namely a factor of about 2.…”
Section: Flow Ratementioning
confidence: 56%
“…19,26 Over the pH-range investigated presently (5.0-7.0), the quinuclidine ring is protonated throughout and thus the WAX-type CSP has a reasonable anion-exchange capacity. Moreover, in this pH range also the carboxylic acid functionalities of the analytes (pK a -values of COOH groups < 4.6; pI values of the acidic amino acids range between 4.6 and 5.6) are ionized thus enabling attractive electrostatically driven selector-solute interactions.…”
Section: Effect Of Eluent Phmentioning
confidence: 99%
See 1 more Smart Citation
“…13 Recently, much work has been reported describing the use of chiral stationary phases, in conjugation with HPLC, as a way to separate and thereby individually quantitative the enantiomers of an enantiomeric pair. [14][15][16] The chiral nature of the drug has made the importance to develop the chiral HPLC method for the enantiomeric purity and quantitative determination of undesired isomer.…”
Section: Repaglinide (Figure 1) Single Enantiomer Is Chemically (S)-(mentioning
confidence: 99%