2021
DOI: 10.1016/j.jpba.2021.114215
|View full text |Cite
|
Sign up to set email alerts
|

HPLC-UV-HRMS analysis of cannabigerovarin and cannabigerobutol, the two impurities of cannabigerol extracted from hemp

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
12
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 9 publications
(12 citation statements)
references
References 18 publications
0
12
0
Order By: Relevance
“…The column was re-equilibrated at 70% ACN for further 3 min for a total run time of 26 min at a constant ow rate of 0.5 mL/min. The HESI parameters were optimized in previous works for cannabinoids: spray voltage 4200 kV and 3800 kV for HESI + and HESI-mode respectively, sheath gas 70 au, auxiliary gas 5 au, sweep gas 0.5 au, ion transfer tube temperature 390°C and vaporizer temperature 150°C 23,25 . The mass analyzer was operated in both full scan (FS) and data-dependent acquisition (DDA) mode.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The column was re-equilibrated at 70% ACN for further 3 min for a total run time of 26 min at a constant ow rate of 0.5 mL/min. The HESI parameters were optimized in previous works for cannabinoids: spray voltage 4200 kV and 3800 kV for HESI + and HESI-mode respectively, sheath gas 70 au, auxiliary gas 5 au, sweep gas 0.5 au, ion transfer tube temperature 390°C and vaporizer temperature 150°C 23,25 . The mass analyzer was operated in both full scan (FS) and data-dependent acquisition (DDA) mode.…”
Section: Methodsmentioning
confidence: 99%
“…In FS mode the resolution was set at 60,000 FWHM (full width at half maximum), the RF lens level at 70%, the maximum injection time 54 ms, the m/z range at 150-750, and the isolation window at m/z 1.2. In DDA mode the resolution was set at 30,000 FWHM, the maximum injection time at 22 ms, the m/z range at 50-750, the isolation window at m/z 1.2, and the stepped normalized collision energy (NCE) at 20-40-100 23,25 . The injection volume was 5 µL.…”
Section: Methodsmentioning
confidence: 99%
“…Most commonly used MS analyzers include simple Q spectrometers [ 181 ], QQQ analyzers [ 11 , 58 , 68 , 97 , 114 , 147 , 193 , 194 ], IT analyzers [ 28 , 43 , 72 , 185 ], QTRAP [ 67 , 159 , 191 , 195 ] or high resolution-accurate mass MS (HRAM-MS) analysers, such as Q-TOF [ 83 , 88 , 139 , 189 ] and Q-Exactive TM Orbitrap [ 19 , 63 , 65 , 66 ].…”
Section: Analytical Methods For Phytocannabinoid Profilingmentioning
confidence: 99%
“…Phytocannabinoid profiling is most commonly performed using ESI, rarely using variations such as dual source [ 78 ] or heated ESI source [ 19 , 63 ]. Acquisitions are performed in positive (+) [ 88 , 147 , 189 , 191 , 193 , 194 ], negative (−) [ 134 ] or both (+) and (−) modes [ 27 , 40 , 55 , 62 , 63 , 64 , 92 , 144 , 178 , 181 ]. In fact, all major phytocannabinoids are detected in both ionization modes, except for THCV [ 78 ].…”
Section: Analytical Methods For Phytocannabinoid Profilingmentioning
confidence: 99%
See 1 more Smart Citation