Review of Progress in Quantitative Nondestructive Evaluation 1997
DOI: 10.1007/978-1-4615-5947-4_278
|View full text |Cite
|
Sign up to set email alerts
|

HTS-SQUID Magnetometer with Digital Feedback Control for NDE Applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

1997
1997
2021
2021

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 5 publications
0
5
0
Order By: Relevance
“…Experimentally, dynamic ranges of up to of 8 × 10 4 0 were demonstrated [86]. A short integrator reset time is essential to allow a high system slew rate [6].…”
Section: Dynamic Rangementioning
confidence: 99%
See 1 more Smart Citation
“…Experimentally, dynamic ranges of up to of 8 × 10 4 0 were demonstrated [86]. A short integrator reset time is essential to allow a high system slew rate [6].…”
Section: Dynamic Rangementioning
confidence: 99%
“…Flux-quanta counting can be conveniently implemented in a digital feedback electronics. Here, the analogue output of the preamplifier is digitized, integrated digitally and fed back into the SQUID via a digital-to-analogue (D/A) converter [85,86]. The digital integrator can easily be reset and yields the digitized feedback signal with an accuracy given by the D/A converter.…”
Section: Dynamic Rangementioning
confidence: 99%
“…• Flux counting electronics [51][52][53] • Hybrid SQUIDs exploit the deformed voltage-fluxcharacteristics of a dc SQUID with additional positive feedback [56][57][58] to gain a steep slope for flux quanta counting and a flat slope for the fractions of one flux quantum; both numbers will be merged to provide a hybrid readout of the magnetic field amplitude (Leibniz IPHT, unpublished), • Digital SQUIDs [59][60][61][62][63][64][65] with digitization at the cryostage(s); however, most implementations of digital superconductor electronics are so far not operational in Earth field and require at least a moderate shielding e.g. [64,66], • Flux ramp modulation readout which read out the phase of a dc SQUID voltage-flux-characteristics driven by a fast sinusoidal signal [67] (significantly faster than the signals to be measured).…”
Section: High Dynamic Range Magnetometersmentioning
confidence: 99%
“…The resolution data refer to the white noise region measured in magnetically shielded environment. The rf magnetometers were operated with a digital signal processor controlled flux-locked loop electronics [10,11], the dc gradiometers with a commercial electronics.…”
Section: Squ/ds and Electronicsmentioning
confidence: 99%