2016
DOI: 10.1002/pat.3984
|View full text |Cite
|
Sign up to set email alerts
|

Human serum albumin in electrospun PCL fibers: structure, release, and exposure on fiber surface

Abstract: Human serum albumin (HSA) introduced to the fibers produced by electrospinning from HSA and polycaprolactone (PCL) solutions in hexafluoroisopropanol has been studied in terms of its structure, release from the fibers, stability of interaction with basic polymer, accessibility for protease attack, and cellular receptors, as well as dependence of the studied parameters on the protein concentration in fibers. A limited part of the protein leaves the fibers right after soaking with water, whereas the remaining pr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
34
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 27 publications
(37 citation statements)
references
References 44 publications
3
34
0
Order By: Relevance
“…The microstructure of the matrix surface was studied using scanning electron microscopy (SEM), (JSM-6460 LV, Jeol, Tokyo, Japan) as described previously [20] and atomic force microscopy (AFM) with Multimode 8 (Bruker, Germany) using NSG10-DLC diamond-like carbon NSG series AFM cantilever (NT-MDT, Zelenograd, Russia) in tapping mode. Fiber diameter and pore size were calculated from SEM images according to ISO 7198:1998 using AxioVision 4.8 software (Carl Zeiss, Gottingen Germany).…”
Section: Analysis Of Matrix Surface Structure and Propertiesmentioning
confidence: 99%
See 4 more Smart Citations
“…The microstructure of the matrix surface was studied using scanning electron microscopy (SEM), (JSM-6460 LV, Jeol, Tokyo, Japan) as described previously [20] and atomic force microscopy (AFM) with Multimode 8 (Bruker, Germany) using NSG10-DLC diamond-like carbon NSG series AFM cantilever (NT-MDT, Zelenograd, Russia) in tapping mode. Fiber diameter and pore size were calculated from SEM images according to ISO 7198:1998 using AxioVision 4.8 software (Carl Zeiss, Gottingen Germany).…”
Section: Analysis Of Matrix Surface Structure and Propertiesmentioning
confidence: 99%
“…Polytetrafluoroethylene rings were also installed in control wells to make the free bottom surface area even across all the wells. Following 48 h cultivation, the viability of endothelial cells was assessed using Alamar Blue (Invitrogen, Eugene, Oregon, USA) as described previously [20]. Matrices not seeded with cells were used as control for dye sorption on the material, and the surface of the 3D matrices (after O-ring installation) was taken into account in the further estimations.…”
Section: Assessment Of Adhesion and Viability Of Endothelial Cells Onmentioning
confidence: 99%
See 3 more Smart Citations