1982
DOI: 10.1109/tmtt.1982.1131333
|View full text |Cite
|
Sign up to set email alerts
|

Human Whole-Body Radiofrequency Absorption Studies Using a TEM-Cell Exposure System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

1983
1983
2016
2016

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 27 publications
(11 citation statements)
references
References 18 publications
0
11
0
Order By: Relevance
“…The methods used will only be briefly reviewed here since they have been described in detail in two previous reports [Hill, 1982b;Hill and Walsh, 19831.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The methods used will only be briefly reviewed here since they have been described in detail in two previous reports [Hill, 1982b;Hill and Walsh, 19831.…”
Section: Methodsmentioning
confidence: 99%
“…The original tests on the measurement system led to the conclusion that the total uncertainty in NSAR values might be as high as +35% [Hill, 1982b], but based on our own published [ibid, Table IV] absorption measurements on cylinders and the measurements of two other groups [Allen et al, 1975;Marshall et al, 19811 on salinefilled prolate spheroids in TEM cells it now appears that the total uncertainty due to systematic errors is no more than k25 % . Since a small interaction between the body and the residual resonances could still be present, at 40.68 MHz, the total dosimetric uncertainty for that one frequency is estimated to be about +40%.…”
Section: Dosimetric Accuracymentioning
confidence: 99%
See 1 more Smart Citation
“…The Eaton probe is connected to a digital oscilloscope by an ordinary coaxial cable, which might affect the results. By plotting I/E as a function of the reciprocal separation distance (cm À1 ), an extrapolation to free space conditions is achieved by using the intercept, e.g., when d À1 0 (d I) [Hill, 1982]. Linear regression analysis has been used to estimate the extrapolation line.…”
Section: Effect Of Shoesmentioning
confidence: 99%
“…TEM cell applications include the emissions and susceptibility testing of electronic equipment for electromagnetic compatibility (EMC) purposes [2][3][4][5][6][7][8], the calibration of antennas and probes [9,10], as well as the study of biological effects of radiofrequency (rf) radiation [11][12][13]. The basic TEM cell design, as shown in figure 1, consists of a section of rectangular coaxial transmission line (RCTL) coupled via tapered sections to ordinary 50 Q coaxial cable.…”
Section: Introductionmentioning
confidence: 99%