Hybrid 23/25-Gauge Direct Perfluorocarbon Liquid—Silicone Oil Exchange

Abstract: Purpose: To describe a novel technique for direct perfluorocarbon liquid (PFCL)-silicone oil exchange that aims to reduce the inherent risk of intraoperative intraocular pressure spike.Methods: We use the conventional setup for passive PFCL-silicone exchange, but intentionally create a mismatch between the passive PFCL aspiration and the active silicone injection that favors the PFCL extrusion. This is achieved by converting one port to a large gauge one-23 or 20-gauge.Results: We did not note the occurrence o… Show more