Hybrid BEEQ tandem mass spectrometer for the study of ion/surface collision processes

Abstract: A hybrid mass spectrometer consisting of a magnetic sector, two electric sectors, and a quadrupole mass filter (BEEQ) has been built for the study of polyatomic ion/surface collision phenomena over the energy range of a few electron volts to several keV. Primary ions are generated by electron ionization or by chemical ionization, and the first two sectors are used to deliver a monoenergetic beam of ions, of a selected mass-to-charge m/z ratio, to a decelerator which sets the desired collision energy. The targe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
52
0

Year Published

1999
1999
2010
2010

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 69 publications
(52 citation statements)
references
References 42 publications
0
52
0
Order By: Relevance
“…The reported values for kinetic energies of fragment ions range up to about 15 eV, although in most cases they are just a few eV, 79,91,95,96 demonstrating the high inelasticity of collisions that lead to SID. In a recent study on biological ions at normal impact 97 very small (ϳ0.1 eV) energies have been measured.…”
Section: Characteristic Parametersmentioning
confidence: 99%
See 1 more Smart Citation
“…The reported values for kinetic energies of fragment ions range up to about 15 eV, although in most cases they are just a few eV, 79,91,95,96 demonstrating the high inelasticity of collisions that lead to SID. In a recent study on biological ions at normal impact 97 very small (ϳ0.1 eV) energies have been measured.…”
Section: Characteristic Parametersmentioning
confidence: 99%
“…͑Note the nomenclature B ϭmagnetic sector, Eϭelectrostatic analyzer, Qϭquadrupole mass filter, and TOFϭtime-of-flight.͒ Since the ion beam leaving the double focusing sector field mass spectrometer is spatially focused onto the exit slit of the mass spectrometer, a special lens system must be used to refocus the ion beam onto the surface, which is typically some distance away. Suitable lens systems for this purpose include a static quadrupole doublet 95 and associated deceleration lens system, as in the instrument at Purdue, or an einzel lens 121 and associated deceleration lens system, as in the instrument at Innsbruck. 108 There are also instruments that use only a single magnetic sector for mass separation of the projectile ions, as in the B-TOF instrument at the University of Osnabrück 122 and the Purdue BQ instrument.…”
Section: B Mass Analyzersmentioning
confidence: 99%
“…45 Briefly, dibromomethane was introduced into the ion source (10 À5 Torr nominal sample pressure) and ionized by electron impact (70 eV). The resulting ions were accelerated to 2 keV translational energy, and mass and energy selected, respectively, by the magnetic and electrostatic analyzers of a double focusing mass spectrometer.…”
Section: Methodsmentioning
confidence: 99%
“…The kinetic energy analyzer was set in a low-resolution mode so as to pass ions of a broad range of energies in the range of a few eV. These conditions are known to efficiently transfer the products of inelastic, reactive, and chemical sputtering processes [36]. The selected conditions give maximum scattered ion transmission without significant angular or velocity discrimination, although the latter types of experiments have been performed earlier, using the same instrumentation.…”
Section: Ion/surface Scattering Experimentsmentioning
confidence: 99%
“…All experiments were performed in a custom-built, hybrid mass spectrometer with geometry BEEQ (B = magnetic sector, E = electric sector, Q = quadrupole mass analyzer), a detailed description of which has been provided [36]. Briefly, volatile samples were independently introduced into the ion source (10 −5 Torr nominal sample pressure) and ionized by electron impact (70 eV).…”
Section: Ion/surface Scattering Experimentsmentioning
confidence: 99%