2014
DOI: 10.1016/j.ijepes.2014.03.071
|View full text |Cite
|
Sign up to set email alerts
|

Hybrid direct power/current control using feedback linearization of three-level four-leg voltage source shunt active power filter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
19
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 33 publications
(19 citation statements)
references
References 28 publications
0
19
0
Order By: Relevance
“…In [14, 21], the reference vector v * is projected on the axes of 60° g–h coordinates system as shown in Fig. 5.…”
Section: Proposed Hybrid Svm Algorithm For N‐level DCCmentioning
confidence: 99%
“…In [14, 21], the reference vector v * is projected on the axes of 60° g–h coordinates system as shown in Fig. 5.…”
Section: Proposed Hybrid Svm Algorithm For N‐level DCCmentioning
confidence: 99%
“…So everything depends on the appropriate choice of this surface [20]. Therefore, for simplicity, Equation (27) has been transformed for the sliding surface for SM-MPPT.…”
Section: Sliding Mode Based Mpptmentioning
confidence: 99%
“…These nonlinear loads draw non-sinusoidal currents from utility grids, which create harmonic currents and low power factors [25,26]. The latter present many harmful effects like power losses, heat and saturation of transformers, and the degradation of electrical devices [25,27]. On the other hand, the increased demand of good quality of power makes the use of power quality improvement devices essential [28], and much research is interested in double function grid-tied PV systems to simultaneously perform power quality improvement and active power injections.The control of double function grid-tied PV system is an effective research field, and numerous control strategies have been discussed in the literature [1,24,[29][30][31].…”
mentioning
confidence: 99%
“…Some methods are based on the idea of adding auxiliary power circuits in order to redistribute the electrical charge between capacitors [28]. A very interesting solution proposed in [29], is to use the 3DSVM to stabilize the capacitors voltages in three-level four-leg inverter. The idea is to minimize a cost function defined as the quadratic sum of the differences between the capacitors voltages and their reference values [29].…”
Section: -The Tuned Frequency Cannot Vary Under the Different Harmonmentioning
confidence: 99%
“…The idea is to minimize a cost function defined as the quadratic sum of the differences between the capacitors voltages and their reference values [29]. Thanks to an appropriate selection of the redundant vectors this function can be minimized to zero and the capacitors voltages will be kept at their reference values [29].…”
Section: -The Tuned Frequency Cannot Vary Under the Different Harmonmentioning
confidence: 99%