2021
DOI: 10.3390/en14051390
|View full text |Cite
|
Sign up to set email alerts
|

Hybrid Islanding Detection Method of Photovoltaic-Based Microgrid Using Reference Current Disturbance

Abstract: This paper proposes a new hybrid islanding detection method for grid-connected photovoltaic system (GCPVS)-based microgrid. In the presented technique, the suspicious islanding event is initially recognized whilst the absolute deviation of the point of common coupling (PCC) voltage surpasses a threshold. After an intentional delay, a transient disturbance is injected into the voltage source inverter’s d-axis reference current to decline the active power output. As a result, the PCC voltage reduces in islanding… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 8 publications
(8 citation statements)
references
References 25 publications
0
8
0
Order By: Relevance
“…The combination of both active‐ and passive‐based methods significantly reduces the overall NDZ compared to the pure passive IDM without violating the PQ standards in grid‐connected mode. As an instance of hybrid schemes, the active power output of GCPVS has been reduced through a current injection into I d ,ref during suspicious islanding events, categorised by an absolute voltage deviation index [58]. This power curtailment leads to a further voltage reduction; thus, islanding is recognised when voltage and active power output drop below pre‐defined thresholds simultaneously.…”
Section: Islanding Detection Methodologies For Grid‐connected Photovo...mentioning
confidence: 99%
See 2 more Smart Citations
“…The combination of both active‐ and passive‐based methods significantly reduces the overall NDZ compared to the pure passive IDM without violating the PQ standards in grid‐connected mode. As an instance of hybrid schemes, the active power output of GCPVS has been reduced through a current injection into I d ,ref during suspicious islanding events, categorised by an absolute voltage deviation index [58]. This power curtailment leads to a further voltage reduction; thus, islanding is recognised when voltage and active power output drop below pre‐defined thresholds simultaneously.…”
Section: Islanding Detection Methodologies For Grid‐connected Photovo...mentioning
confidence: 99%
“…Therefore, the interaction between these features and islanding detection should draw more attention in future studies. • Several hybrid methodologies employed a voltage-based criterion to identify the suspicious islanding events [58,[62][63][64].…”
Section: Conclusion and Recommendations For Future Improvementsmentioning
confidence: 99%
See 1 more Smart Citation
“…There is much research on attaining fast detection times with a smaller non-detection zone [98]. Based on the method implemented to identify abnormality, the anti-islanding protection scheme is categorized into active [99], passive [100] and hybrid [101] islanding detection. In active islanding detection, an external perturbation is added into the system, and variation in the signal is observed to identify any abnormality.…”
Section: Grid-connected Inverter Controlmentioning
confidence: 99%
“…Nonetheless, the method relies on communication infrastructure, hindering its decentralized applicability. Finally, Bakhshi-Jafarabadi & Popov [13] introduced an HDM based on a series PDM-ADM. The PDM is based on the ROCOV at the PCC.…”
Section: Introductionmentioning
confidence: 99%