2023
DOI: 10.1016/j.bspc.2023.104972
|View full text |Cite
|
Sign up to set email alerts
|

Hybrid modeling on reconstitution of continuous arterial blood pressure using finger photoplethysmography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
7
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 33 publications
(7 citation statements)
references
References 42 publications
0
7
0
Order By: Relevance
“…With PPG sensors being extremely sensitive to even the slightest movement, and the MA spectrum overlapping with the HR spectrum, MA detection and removal has been a field of research in recent years, unfortunately with no satisfactory results [ 7 , 12 , 16 , 17 , 18 , 19 , 21 ]. This fact significantly complicates the task of maintaining consistently clean PPG signals, especially concerning endeavors such as estimating blood pressure from PPG data, which is a popular area of investigation [ 35 ]. The accuracy and fidelity of deriving ABP waveforms from PPG signals heavily rely on the absence of artifacts, particularly motion-induced distortions.…”
Section: Discussionmentioning
confidence: 99%
“…With PPG sensors being extremely sensitive to even the slightest movement, and the MA spectrum overlapping with the HR spectrum, MA detection and removal has been a field of research in recent years, unfortunately with no satisfactory results [ 7 , 12 , 16 , 17 , 18 , 19 , 21 ]. This fact significantly complicates the task of maintaining consistently clean PPG signals, especially concerning endeavors such as estimating blood pressure from PPG data, which is a popular area of investigation [ 35 ]. The accuracy and fidelity of deriving ABP waveforms from PPG signals heavily rely on the absence of artifacts, particularly motion-induced distortions.…”
Section: Discussionmentioning
confidence: 99%
“…Thus, PPG holds advantages for extending applications in health and medical fields, such as biometric authentication, patient monitoring, and fall detection. For instance, a recent study utilizing finger PPG reconstructed ambulatory blood pressure (ABP) for further medical applications [ 24 , 25 ]. To facilitate the practical application of PPG, we herein propose and evaluate an HAR system based on PPG signals newly collected from 40 participants while performing daily activities.…”
Section: Introductionmentioning
confidence: 99%
“…The derived signal from the PPG sensor is called the blood volume pulse (BVP), and it is the measurement of changes in blood volume in arteries and capillaries. Interestingly, changes in the BVP signal can reflect changes in blood pressure [23], which may correspond to levels of exertion characterizing some types of activities [24]. These attributes make it a promising modality for a wide array of applications, including but not limited to human activity monitoring [17,[25][26][27].…”
Section: Introductionmentioning
confidence: 99%