2015
DOI: 10.1016/j.cej.2015.06.118
|View full text |Cite
|
Sign up to set email alerts
|

Hybrid [polysulfone–Zero Valent Iron] membranes: Synthesis, characterization and application for AsIII remediation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
7
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 26 publications
(8 citation statements)
references
References 48 publications
(86 reference statements)
1
7
0
Order By: Relevance
“…For the measurements we used aliquots of 8.3 mL shifting at pH < 0.5 by 1.5 mL from 6.66 M of HCl and final 2 M concentration in the electrochemical cell [25], then 8 ppm of Cu 2+ were added. In the following, As III was determined by SW-CSV with accumulation potential E = −400 mV and accumulation time 60 s. As III was quantified by its signal at E 1/2 = −670 mV [19,20]. For the kinetic measurements, As III uptake from aqueous solutions was studied in batch experiments.…”
Section: Analytical Determination Of As IIImentioning
confidence: 99%
See 2 more Smart Citations
“…For the measurements we used aliquots of 8.3 mL shifting at pH < 0.5 by 1.5 mL from 6.66 M of HCl and final 2 M concentration in the electrochemical cell [25], then 8 ppm of Cu 2+ were added. In the following, As III was determined by SW-CSV with accumulation potential E = −400 mV and accumulation time 60 s. As III was quantified by its signal at E 1/2 = −670 mV [19,20]. For the kinetic measurements, As III uptake from aqueous solutions was studied in batch experiments.…”
Section: Analytical Determination Of As IIImentioning
confidence: 99%
“…To test the recyclability of the gC 3 N 4 -rFe material we have used the methodology described earlier in reference [20] for Fe-particles supported on polysulfone membranes. Reusing the gC 3 N 4 -rFe requires to desorb the adsorbed As III .…”
Section: Reusability Of Gc 3 N 4 -Rfementioning
confidence: 99%
See 1 more Smart Citation
“…Finally, we have evaluated the possibility of reusing the ZrMOF and ZrMOF@SF d materials after regeneration. Thus, we have applied the regeneration protocol 24,70 , which involved high ionic-strength treatment. More particularly, the protocol involves incubation for 24 hours under stirring at a pure aqueous solution containing 1 M of KNO 3 .…”
Section: ( ) [Ii]mentioning
confidence: 99%
“…In fact, there are reported studies on the use of ferric oxide on PSf membranes. A recent study by Georgiou et.al (2015) showed that a nanocomposite membrane of PSf/zero valent iron (ZVI) illustrated a significant enhancement of mechanical robustness whereas a study by Greenlee (2015) successfully demonstrated that the PSf/ZVI may also function as a hybrid adsorbent for the remediation of arsenic (III) (Georgiou et al, 2015;Greenlee, 2015). In addition, a study by Chen et.al.…”
Section: Introductionmentioning
confidence: 99%