2011
DOI: 10.1002/oca.933
|View full text |Cite
|
Sign up to set email alerts
|

Hybrid predictive control of a DC–DC boost converter in both continuous and discontinuous current modes of operation

Abstract: Developing efficient and appropriate modeling and control techniques for DC-DC converters is of major importance in power electronics area and has attracted much attention from automatic control theory. Since DC-DC converters have a complex hybrid nature, recently several techniques based on hybrid modeling and control have been introduced. These techniques have shown better results as compared with conventional averaging-based schemes with limited modeling and control abilities. But the current works in this … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
24
0
1

Year Published

2016
2016
2021
2021

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 15 publications
(25 citation statements)
references
References 29 publications
0
24
0
1
Order By: Relevance
“…Furthermore, it provides an environment for the users to obtain low complexity MLD models with their own knowledge, heuristics, modeling art, and ideas. (vi) In the application side, this paper improves the previous studies on the MLD modeling and predictive control of DC‐DC converters in both continuous and discontinuous conduction modes from the complexity point of view . As another benchmark, a tank system is considered as a basic component of any process control system.…”
Section: Introductionmentioning
confidence: 83%
See 3 more Smart Citations
“…Furthermore, it provides an environment for the users to obtain low complexity MLD models with their own knowledge, heuristics, modeling art, and ideas. (vi) In the application side, this paper improves the previous studies on the MLD modeling and predictive control of DC‐DC converters in both continuous and discontinuous conduction modes from the complexity point of view . As another benchmark, a tank system is considered as a basic component of any process control system.…”
Section: Introductionmentioning
confidence: 83%
“…Equations (37) and (38) mean that, at each instant k, either only one of the invariant conditions or one of the guard conditions with reset dynamic in the DHA is satisfied. The terms in (37) and (38) are simplified to…”
Section: Proposition 2 Each Deterministic and Nonblocking Dha Can Bementioning
confidence: 99%
See 2 more Smart Citations
“…İdeal olarak, çevirici giriş ve çıkış gerilimi arasındaki ilişki sistem parametrelerinden bağımsız anahtarlama oranına bağlı cebirsel olarak elde edilebilir. Ancak pratikte, ideal olmayan çevirici elemanları (pasif elemanlar ve anahtarlama elemanları) ve çeviricinin kesintili akım modunda çalışması durumu, çeviricinin ilgili çalışma noktası için belli bir anahtarlama oranının belirlenmesini olanaksız kılar [7]. Bu sebeple çeviriciye ait anahtarlama oranının elde edilmesi için, referans ve gerçek çıkış gerilimlerine dayalı bir geri beslemeli kontrol yapısının kullanılması zorunludur [8].…”
Section: Gi̇ri̇ş (Introduction)unclassified