2011
DOI: 10.1111/j.1600-0846.2011.00573.x
|View full text |Cite
|
Sign up to set email alerts
|

Hydration measurements of the stratum corneum: comparison between the capacitance method (digital version of the Corneometer CM 825®) and the impedance method (Skicon‐200EX®)

Abstract: Both instruments allow a certain calibration and both give good estimates of the SC hydration.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
117
3
3

Year Published

2014
2014
2021
2021

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 121 publications
(125 citation statements)
references
References 12 publications
2
117
3
3
Order By: Relevance
“…Computational studies of the thermal and electrical responses relied on commercial software from ABAQUS 9 and COMSOL 10 , respectively. For the former, the encapsulation layer (Ecoflex), skin, and heater used axisymmetric heat transfer elements (DCAX4).…”
Section: Materials and Methods Fabrication Of Integrated Sensorsmentioning
confidence: 99%
See 2 more Smart Citations
“…Computational studies of the thermal and electrical responses relied on commercial software from ABAQUS 9 and COMSOL 10 , respectively. For the former, the encapsulation layer (Ecoflex), skin, and heater used axisymmetric heat transfer elements (DCAX4).…”
Section: Materials and Methods Fabrication Of Integrated Sensorsmentioning
confidence: 99%
“…Thermal measurements (1) are less susceptible to contact resistances due to the increased penetration depth of the thermal signal (as seen in the FEA shown in Figure 4; (2) do not require direct contact, allowing for a soft elastomeric layer to provide further insulation from leakage currents into the skin (in addition to the stiff, PI layer) 15 , in addition to imparting robustness to the device, unlike impedancebased sensors where the electrodes need be in direct contact with skin 19 ; and (3) offer advanced capabilities in temperature 16 and blood flow mapping 17 using similar resistive elements. Impedance-based measurements (1) build on an extensive library of knowledge on skin-based electrical measurements 25,44 ; (2) provide versatility in probing volumes derived from the ability to use a wide range of applied frequencies 45 ; (3) yield physical information about skin through both the capacitive reactance (permittivity) and the resistance (conductivity) 23 embedded in the measured impedance; and (4) enable comparisons with existing commercial measurements, almost all of which rely on electrical sensing 9 . Both measurements offer comparably short speeds, with a complete impedance spectral sweep requiring roughly the same amount of time as a time-multiplexed measurement of 16 individual ETPS elements (both~10 s).…”
Section: Depth Of Measurementmentioning
confidence: 99%
See 1 more Smart Citation
“…Capacitance is considered a function of SC hydration (16). Measurements were performed on each of the two test areas at baseline as well as at 2, 4, 8, and 24 h after the first and single application of NTP-CE.…”
Section: Subjects and Assessmentsmentioning
confidence: 99%
“…, ranging from 0 to 120 a.u. A higher capacitance value indicates a higher moisturizing effect on the skin 19,20 .…”
Section: Methodsmentioning
confidence: 99%