Hydraulic and thermal studies on a chevron type plate heat exchanger

Abstract: The present work deals with the experimental study of a single pass U-type chevron plate heat exchanger using liquid-liquid combination in both the channels for the range of Reynolds numbers, 800-5900. The influence of Reynolds number, pumping power and number of plates on the hydraulic and thermal performance of plate heat exchager are presented. Results are predicted for a chevron angle of β=60 o and fixed port size dp =25.4 mm for a different set of plates, namely, 15, 21, and 27 under two different conditi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 20 publications
0
3
0
Order By: Relevance
“…Finally, they pointed out that the study shows potential to work in environments of severe and corrosive wear or with hygiene requirements. Kumar and Singh [7] conducted an experimental study on a plate heat exchanger and presented thermal and hydraulic performance results with Reynolds numbers ranging between 800 and 5900. They use a chevron plate with an angle equal to 60º in isothermal or non-isothermal conditions.…”
Section: Introductionmentioning
confidence: 99%
“…Finally, they pointed out that the study shows potential to work in environments of severe and corrosive wear or with hygiene requirements. Kumar and Singh [7] conducted an experimental study on a plate heat exchanger and presented thermal and hydraulic performance results with Reynolds numbers ranging between 800 and 5900. They use a chevron plate with an angle equal to 60º in isothermal or non-isothermal conditions.…”
Section: Introductionmentioning
confidence: 99%
“…Pantzali et al [31] explained experimentally and numerically the effect of nanofluid as working fluid for a miniature PHE. The Computational Fluid Dynamics (CFD) is helpful in designing, optimization, and solving the mathematical equation [32][33][34].…”
Section: Introductionmentioning
confidence: 99%
“…Kumar and Singh [7] conducted an experimental study on a plate heat exchanger and presented thermal and hydraulic performance results with Reynolds numbers ranging between 800 and 5900. They use a chevron plate with an angle equal to 60 • in isothermal or non-isothermal conditions.…”
Section: Introductionmentioning
confidence: 99%