2000
DOI: 10.1007/s002619910005
|View full text |Cite
|
Sign up to set email alerts
|

Hydro-MRI for the visualization of gastric wall motility using RARE magnetic resonance imaging sequences

Abstract: The purpose of this study was to demonstrate a new technical approach for a noninvasive dynamic study of gastric motor function with hydro-MRI. This robust method may have clinical application, e.g., in the diagnosis of gastroparesis, and may be extended to the rest of the gastrointestinal tract.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
19
0
5

Year Published

2002
2002
2014
2014

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 32 publications
(24 citation statements)
references
References 12 publications
0
19
0
5
Order By: Relevance
“…This reflects the lack of sufficient spatial resolution to depict the gastric mucosal surfaces. The MRbased analysis of functional heart and gastric disorders, on the other hand, seems to have considerably more potential [20,[24][25][26].…”
Section: Discussionmentioning
confidence: 99%
“…This reflects the lack of sufficient spatial resolution to depict the gastric mucosal surfaces. The MRbased analysis of functional heart and gastric disorders, on the other hand, seems to have considerably more potential [20,[24][25][26].…”
Section: Discussionmentioning
confidence: 99%
“…The propagation velocity averages 2.5 mm/s, and increases from the proximal to the distal stomach. Each contraction takes approximately 1 min to advance from the fundus to the pylorus (Bilecen and others 2000; Kwiatek and others 2006; Schulze 2006).…”
Section: Stomach Physiology and Food Digestionmentioning
confidence: 99%
“…As the peristaltic wave reaches the pylorus, the contraction width increases and indentations deepen, often virtually occluding the antral lumen, a process referred to as “terminal antral contraction” (Bilecen and others 2000; Schulze 2006). Meanwhile, the pylorus contracts and the sphincter narrows, so that the pyloric opening is small on the arrival of the peristaltic wave.…”
Section: Stomach Physiology and Food Digestionmentioning
confidence: 99%
“…To assess gastric motility, a fast two-dimensional (2D) dynamic scan (such as turbo field echo, turbo spin echo, echo planar imaging, true FISP, balanced FFE, RARE) has been advocated [4, 5, 7, 15, 19, 20]. There is no particular preference for a specific acquisition technique, as the only goal of the technique is to be sufficiently fast to reach a temporal resolution that is high enough to analyze gastric motility with MRI.…”
Section: Technical Aspects Of Gastric Mrimentioning
confidence: 99%