2022
DOI: 10.1016/j.est.2022.105102
|View full text |Cite
|
Sign up to set email alerts
|

Hydro-thermal preparation of PbCO3/N-rGO nano-composites as positive additives to improve the performance of lead-acid batteries

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(4 citation statements)
references
References 46 publications
0
4
0
Order By: Relevance
“…In addition, the electrode-specific capacitance (C p ) can be calculated on the basis of the size of the oxidation and reduction peak areas. In accordance with the calculation formula for specific capacitance, C p = i false( v false) d v 2 m υ false( v 2 v 1 false) (V 1 and V 2 are the starting and ending voltages of the scan, m is the mass of the active material in grams, and υ is the scan rate in V s –1 ), the C p values for the blank, CCB, and Bi 2 O 3 @C-4 negative plates are 33.8, 47.3, and 56.7 F/g, respectively. When the electrode-specific capacitance is larger, the electrode can store more charge.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…In addition, the electrode-specific capacitance (C p ) can be calculated on the basis of the size of the oxidation and reduction peak areas. In accordance with the calculation formula for specific capacitance, C p = i false( v false) d v 2 m υ false( v 2 v 1 false) (V 1 and V 2 are the starting and ending voltages of the scan, m is the mass of the active material in grams, and υ is the scan rate in V s –1 ), the C p values for the blank, CCB, and Bi 2 O 3 @C-4 negative plates are 33.8, 47.3, and 56.7 F/g, respectively. When the electrode-specific capacitance is larger, the electrode can store more charge.…”
Section: Resultsmentioning
confidence: 99%
“…(V 1 and V 2 are the starting and ending voltages of the scan, m is the mass of the active material in grams, and υ is the scan rate in V s −1 ), 57 the C p values for the blank, CCB, and Bi 2 O 3 @C-4 negative plates are 33.8, 47.3, and 56.7 F/g, respectively. When the electrodespecific capacitance is larger, the electrode can store more charge.…”
Section: Electrochemical Performance Of Negativementioning
confidence: 99%
“…Taking into account the challenge of the modern world, even these batteries continue to be improved and currently efforts are being made to improve the performance of lead-acid batteries and extend their life cycle. One of the examples most often cited in recent articles is to improve the discharge capacity of lead-acid batteries, for example, through the use of graphene oxide [10]. Electricity storage technologies were divided into two groups: batteries and accumulation systems.…”
Section: Lead-acid Batterymentioning
confidence: 99%
“…[29][30][31] Some studies inhibited HER by combining active carbon with metals with a high hydrogen evolution overpotential. [32][33][34] Hu et al used silkworm manure and waste lead paste to prepare additives to suppress HER. [35] Zhao et al avoided HER using indium-modified activated carbon.…”
Section: Introductionmentioning
confidence: 99%