Hydrogen Sensor to Monitor the Conditions in the Primary Circuit of a Nuclear Reactor

Abstract: A hydrogen concentration measurement device is developed for nuclear reactor primary circuits water. Despite the necessity to monitor hydrogen, only one producer offers a really selective hydrogen sensor on the world market because of the complexity of the device preparation when long‐term signal stability is required. Therefore, the Mass Transfer Laboratory at UCT Prague shares the experience gained during the sensor development. The results of the amperometric hydrogen sensor laboratory tests are presented, … Show more