2022
DOI: 10.1016/j.petrol.2021.109235
|View full text |Cite
|
Sign up to set email alerts
|

Hydrolysis of imidazoline based corrosion inhibitor and effects on inhibition performance of X65 steel in CO2 saturated brine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
9
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 32 publications
(9 citation statements)
references
References 27 publications
0
9
0
Order By: Relevance
“…Electrochemical impedance spectroscopy (EIS) was completed in the frequency range of 0.1 Hz to 100 kHz with a sine amplitude of 10 mV at E ocp . Corrosion current density (j cor ) was determined by the extrapolation of anodic and cathodic Tafel lines to corrosion potential (E cor ) [6].…”
Section: Corrosion Protection Evaluationmentioning
confidence: 99%
See 1 more Smart Citation
“…Electrochemical impedance spectroscopy (EIS) was completed in the frequency range of 0.1 Hz to 100 kHz with a sine amplitude of 10 mV at E ocp . Corrosion current density (j cor ) was determined by the extrapolation of anodic and cathodic Tafel lines to corrosion potential (E cor ) [6].…”
Section: Corrosion Protection Evaluationmentioning
confidence: 99%
“…Corrosion inhibitors are one of the experimental approaches used for protection against corrosion, specifically in acidic solutions [4][5][6][7][8]. The various inhibitors that have been applied and test industrially as corrosion additives [9][10][11][12] are those are low-or nontoxic are currently better than the materials used in the recent past such as glucose, gellan gum, carboxymethyl, hydroxypropyl cellulose [9,11], xanthan gum [10], and chitosan-g-PEG [12].…”
Section: Introductionmentioning
confidence: 99%
“…For complex mortar, hydration products at the metal-hydrated cement paste interface may affect the onset of localized corrosion, complicating the analysis of the The formation velocity and the long-term stability of the protective film are among the most important indicators to evaluate the efficiency of inhibitors. However, organic substances can disintegrate the form of the steel bar surface due to the desorption effect, leading to a lack of long-term stability [16,17]. On the other hand, the inorganic inhibitors become non-effective in high alkaline conditions because the formation velocity of inorganic inhibitors on steel bars is lower than the corrosion reaction introduced by chloride.…”
Section: Introductionmentioning
confidence: 99%
“…Surface analyses were done by scanning electron microscopy (SEM) and energy dispersive X-ray (EDAX) analyses. The inhibition efficiency of this inhibitor has been reported at 92% in the presence of CO 2 (Sweet environment) for mild steel [13][14][15][16][17].…”
Section: Introductionmentioning
confidence: 99%