2013
DOI: 10.1016/j.jpba.2013.01.022
|View full text |Cite
|
Sign up to set email alerts
|

Hydrophilic interaction chromatography with aerosol-based detectors (ELSD, CAD, NQAD) for polar compounds lacking a UV chromophore in an intravenous formulation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0
1

Year Published

2013
2013
2018
2018

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 16 publications
(9 citation statements)
references
References 13 publications
0
8
0
1
Order By: Relevance
“…As described earlier, Cintrón and Risley measured nonchromophoric drug substances in a mannitol intravenous formulation using HILIC with three different aerosol-based detectors (ELSD, CAD and NQAD) [83]. All three detector-types provided satisfactory results for mannitol and the test drug, although CAD and NQAD had the lowest LODs and required additional sample dilution.…”
Section: Pharmaceutical Formulationsmentioning
confidence: 84%
See 2 more Smart Citations
“…As described earlier, Cintrón and Risley measured nonchromophoric drug substances in a mannitol intravenous formulation using HILIC with three different aerosol-based detectors (ELSD, CAD and NQAD) [83]. All three detector-types provided satisfactory results for mannitol and the test drug, although CAD and NQAD had the lowest LODs and required additional sample dilution.…”
Section: Pharmaceutical Formulationsmentioning
confidence: 84%
“…Cintrón and Risley [83] evaluated a HILIC method, otherwise primarily developed for use with ELSD for determination of a pharmaceutical substance in a mannitol IV formulation, for linearity and detection limit with CNLSD. The detection limit was found to be 1 g/mL for CNLSD (and CAD), which was 10-50x lower than obtained with ELSD.…”
Section: Small Molecule Pharmaceuticalmentioning
confidence: 99%
See 1 more Smart Citation
“…Following that, according to the difference kind of the detected targets, HILIC applied for chemical drug analysis in formulation and related matrices is summarized. Determination of APIs in complicated formulation is important for the QC of chemical drug in pharmaceutical industry, and various related researches have been proposed through HILIC coupled detection system [83][84][85][86]. In powder for intravenous injection, ␤-lactam antibiotics imipenem, and another active compound cilastatin sodium were determined simultaneously in the presence of degradation product thienamycin [83].…”
Section: Analysis Of Chemical Drug In Formulations and Related Matricesmentioning
confidence: 99%
“…Data transformation must be applied to the ELSD data response to generate a linear function. With data tranformation, ELSDs such as Alltech 800 ELSD and ELSD 3300 have demonstrated excellent linearity in addition to the acceptable accuracy, precision (repeatability and intra‐assay precisions), specificity, robustness, and stability . However, NQAD detector has been demonstrated to be 50‐ and 10‐fold more sensitive than ELSD 800 and ELSD 3300 with LODs of 50,10, and 1 g/mL for ELSD 800, ELSD 3300, and NQAD, respectively.…”
Section: Introductionmentioning
confidence: 99%