2000
DOI: 10.1159/000018830
|View full text |Cite
|
Sign up to set email alerts
|

Hyperintense Basal Ganglia on T1-Weighted Magnetic Resonance Images following Postoperative Parenteral Nutrition in a Pancreatoduodenectomized Patient

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2002
2002
2007
2007

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 27 publications
0
5
0
Order By: Relevance
“…An increased T1-weighted (the time associated with the return of longitudinal magnetization to its equilibrium condition is termed the spin lattice relaxation time, T1, and reflects the strength and nature of magnetic interactions between the spins and their atomic neighborhood). Mn signal in the globus pallidus area has been found among workers occupationally exposed to Mn (Dietz et al 2001;Jiang et al, 2006a;Kim et al, 1999a;Lucchini et al, 2000;Nelson et al, 1993), in patients receiving long-term total parenteral nutrition (Alves et al, 1997;Ejima et al, 1992;Fell et al, 1996;Fredstrom et al, 1995;Iwase et al,2000;Nagatomo et al, 1999;Quaghebeur et al, 1996) and in clinical cases of hepatic failure (Butterworth et al, 1995;Chetri et al, 2003;Hauser et al, 1994;Hazell et al 1999;McKinney et al, 2004;Spahr et al, 2002). Kim and his colleagues have reported that a welder with more than 10 years of Mn exposure whose clinical manifestations included a masked face, asymmetric resting tremor and bradykinesia had symmetrical high signal intensities in the globus pallidus on the T1-weighted image.…”
Section: B Search For Biomarker Of Mn Exposurementioning
confidence: 99%
“…An increased T1-weighted (the time associated with the return of longitudinal magnetization to its equilibrium condition is termed the spin lattice relaxation time, T1, and reflects the strength and nature of magnetic interactions between the spins and their atomic neighborhood). Mn signal in the globus pallidus area has been found among workers occupationally exposed to Mn (Dietz et al 2001;Jiang et al, 2006a;Kim et al, 1999a;Lucchini et al, 2000;Nelson et al, 1993), in patients receiving long-term total parenteral nutrition (Alves et al, 1997;Ejima et al, 1992;Fell et al, 1996;Fredstrom et al, 1995;Iwase et al,2000;Nagatomo et al, 1999;Quaghebeur et al, 1996) and in clinical cases of hepatic failure (Butterworth et al, 1995;Chetri et al, 2003;Hauser et al, 1994;Hazell et al 1999;McKinney et al, 2004;Spahr et al, 2002). Kim and his colleagues have reported that a welder with more than 10 years of Mn exposure whose clinical manifestations included a masked face, asymmetric resting tremor and bradykinesia had symmetrical high signal intensities in the globus pallidus on the T1-weighted image.…”
Section: B Search For Biomarker Of Mn Exposurementioning
confidence: 99%
“…One adult patient received TPN for 30 days postoperatively (Iwase et al 2000). On postoperative day 49, the T1-weighted MRI demonstrated bilateral and symmetrical hyperintense lesions in the globus pallidus.…”
Section: The Clearance Of Excessive Manganesementioning
confidence: 99%
“…An increased T1-weighted Mn signal in the globus pallidus area has been found among workers occupationally exposed to Mn (Dietz et al, 2001;Kim et al, 1999b;Lucchini et al, 2000;Nelson et al, 1993), in patients receiving long-term total parenteral nutrition (Alves et al, 1997;Ejima et al, 1992;Fell et al, 1996;Fredstrom et al, 1995;Iwase et al, 2000;Komaki et al, 1999;Nagatomo et al, 1999;Quaghebeur et al, 1996), and in clinical cases reported with hepatic failure (Butterworth et al, 1995;Chetri and Choudhuri, 2003;Hauser et al, 1994;Hazell and Butterworth, 1999;McKinney et al, 2004;Spahr et al, 2002). While in animal models the MRI intensity has been linked to external Mn exposure (Eriksson et al, 1992;Kim et al, 1999a;Misselwitz et al, 1995;Newland et al, 1989a,b;Shinotoh et al, 1995), the question as to how the change in MRI signals in humans is associated with external exposure conditions and whether this consequentially leads to alternations of the internal Mn exposure indices or the fluctuation in blood chemistry remains elusive.…”
Section: Introductionmentioning
confidence: 98%