2019
DOI: 10.1016/j.ultrasmedbio.2019.05.008
|View full text |Cite
|
Sign up to set email alerts
|

I-124-PET/US Fusion Imaging in Comparison to Conventional Diagnostics and Tc-99m Pertechnetate SPECT/US Fusion Imaging for the Function Assessment of Thyroid Nodules

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
21
0
4

Year Published

2019
2019
2024
2024

Publication Types

Select...
4
3
1

Relationship

4
4

Authors

Journals

citations
Cited by 24 publications
(25 citation statements)
references
References 44 publications
0
21
0
4
Order By: Relevance
“…An accurate functional assessment in terms of correct nodule allocation is necessary to identify proper lesions for FNAC. In that regard, the addition of hybrid approaches such as Tc-99m-pertechnetate-SPECT/US and I-124-PET/US fusion imaging has been shown to be superior to CD alone [ 24 , 25 , 26 , 27 , 28 ]. The superimposition of metabolic and morphological images in real-time enables more accurate evaluations of even small or unfavourably located TN and increases the observers’ confidence in the functional assessment of TN, especially on I-124-PET/US fusion imaging.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…An accurate functional assessment in terms of correct nodule allocation is necessary to identify proper lesions for FNAC. In that regard, the addition of hybrid approaches such as Tc-99m-pertechnetate-SPECT/US and I-124-PET/US fusion imaging has been shown to be superior to CD alone [ 24 , 25 , 26 , 27 , 28 ]. The superimposition of metabolic and morphological images in real-time enables more accurate evaluations of even small or unfavourably located TN and increases the observers’ confidence in the functional assessment of TN, especially on I-124-PET/US fusion imaging.…”
Section: Discussionmentioning
confidence: 99%
“…Authors do not recommend the implementation of PET/US into the clinical routine as a standard examination method or to replace scintigraphy. I-124-PET/US fusion imaging is limited by the regional availability of PET/CT scanners, I-124 and suitable US devices with hybrid imaging software as well as by the personnel requirements including the skills needed for accurate fusion imaging and the time expenditure for PET/CT and PET/US examinations [ 27 , 28 ]. Effective whole-body doses of approximately 6.8 mSv derive from I-124-PET/CT scans [ 44 , 45 ].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…It remains unclear if appropriate anatomical landmarks, which are necessary for the creation of a stitched EFOV dataset, can be determined in human subjects. In previous clinical studies investigating fusion imaging in human thyroid glands, the trachea, the hyoid bone, cervical vertebral bodies, and calcified nodules (if applicable), were described as suitable landmarks for the alignment of CT and US images [41]. These constant anatomical structures might be suitable landmarks for the presented stitching method as well.…”
Section: Discussionmentioning
confidence: 99%
“…B. randständig oder dorsal im Schilddrüsenparenchym) häufig Unsicherheiten hinsichtlich der szintigrafischen Charakterisierung, was zu einer relevanten Interobserver-Variabilität führen kann. Hinsichtlich der genannten Limitationen zeigten sich hochsignifikant bessere Ergebnisse, wenn eine ergänzende [ 124 I]-PET/US-Fusionsbildgebung durchgeführt wurde [51,52]. So konnten z.…”
Section: Spectunclassified