1992
DOI: 10.1002/app.1992.070441213
|View full text |Cite
|
Sign up to set email alerts
|

In situ compatibilization of polystyrene/polyethylene blends using amino‐methacrylate‐grafted polyethylene

Abstract: SYNOPSISBlends of a styrene-maleic anhydride copolymer (SMA) with polyethylene ( P E ) or polyethylene melt grafted with tertiary (PE-g-DMAEMA) or secondary ( PE-g-tBAEMA) amino methacrylate were prepared by blending in a batch melt mixer. The morphology of these blends at various compositions was examined with a scanning electron microscope (SEM) and related to their tensile and impact properties. The SMA/PE blends are found to have the typical coarse morphology of incompatible blends and poor mechanical prop… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
16
0

Year Published

1993
1993
2007
2007

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 42 publications
(16 citation statements)
references
References 13 publications
0
16
0
Order By: Relevance
“…Nando et al 16,17 have studied the blends of EMA/PDMS. Recently Song and Baker 18 reported the in situ compatibilization of PS/PE blends. Nando et al 19 was also investigated the in situ compatibilization of LDPE/PDMS using EVA copolymer as a compatibilizer.…”
Section: Introductionmentioning
confidence: 99%
“…Nando et al 16,17 have studied the blends of EMA/PDMS. Recently Song and Baker 18 reported the in situ compatibilization of PS/PE blends. Nando et al 19 was also investigated the in situ compatibilization of LDPE/PDMS using EVA copolymer as a compatibilizer.…”
Section: Introductionmentioning
confidence: 99%
“…Lee et al 12 have investigated the miscibility of LDPE/LLDPE blends. Recently, Song and Baker 13 reported the in situ compatibilization of PS/PE blends using amino methacrylate-grafted polyethylene as the compatibilizer. Nando et al…”
Section: Introductionmentioning
confidence: 99%
“…Capillary rheometers, such as the Instron capillary rheometer and the Monsanto Processability Tester (MPT), have been found to be highly useful in this regard. [13][14][15][16][17][18][19][20][21] Since both EAA and EVA are polar polymers, we expected some kind of chemical interactions that would influence the mechanical performance. From a thorough literature survey, it was noticed that there was no report on the blends of these.…”
mentioning
confidence: 99%
“…81 Melt blends of maleic anhydride grafted poly(styrene) with amino-methacrylate-grafted poly(ethylene) display a somewhat finer morphology and improved mechanical properties. 81 Melt blends of maleic anhydride grafted poly(styrene) with amino-methacrylate-grafted poly(ethylene) display a somewhat finer morphology and improved mechanical properties.…”
Section: Diaminesmentioning
confidence: 99%