In vivoquantification of accumulating abdominal fluid using an electrical impedance tomography hemiarray

Abstract: A new method to image and quantify intra-abdominal haemorrhage using electrical impedance tomography (EIT) was tested in vivo. Supine peritoneal dialysis patients were monitored using an 8-electrode hemiarray placed on the anterior abdomen. EIT measurements were recorded using the EPack II data acquisition system before, during, and after the administration of dialysate. The amount of dialysate infused was recorded synchronous with EIT measurements and used as a control. Tomographic images of impedance change … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
7
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 42 publications
0
7
0
Order By: Relevance
“…We hence made the sensitivity more uniform using the weighted minimum norm method (WMNM) [32]. In WMNM, columns of the matrix are equalized in terms of its power before pseudo-inversion and recovered by rescaling the pixels.…”
Section: Methodsmentioning
confidence: 99%
“…We hence made the sensitivity more uniform using the weighted minimum norm method (WMNM) [32]. In WMNM, columns of the matrix are equalized in terms of its power before pseudo-inversion and recovered by rescaling the pixels.…”
Section: Methodsmentioning
confidence: 99%
“…The effect of fluid balance on changes in electrical impedance of human body is well known and widely used in bioelectrical impedance analysis for determination of total body water 10,11 . There are studies that described the effect of fluid accumulation in peritoneum 12,13 , diuresis 14 or intravenous fluid administration 15 upon the changes of thoracic impedance as determined by EIT. However, to the best of our knowledge, there is no study dealing with the direct comparison of lung volume related changes in EIT with those caused by fluid administration.…”
Section: Introductionmentioning
confidence: 99%
“…Due to blood having a much higher conductivity than many abdominal tissues (about six times [6]), another possible clinical application of EIT is the monitoring of acute intra-abdominal hemorrhages (IAH) [33,34]. IAH is a common consequence of blunt trauma caused by automobile accidents, falls, or detonations and may be undetected from normal clinical signs [14].…”
mentioning
confidence: 99%
“…This indicates a need for an approach that does not involve lifting the patient to place the electrode array, such as applying fewer electrodes to only the anterior surface of the abdomen. Using such a 'hemiarray' configuration produces severe artifacts in reconstructed EIT images, with the worst characterization of conductivity properties far away from electrodes [31,34]. However, quantities derived from images, such as the sum of pixel values, were well correlated with the amount of conductive dialysis fluid infused, and the lowest detectable bleeding rate was similar for hemiarrays and circumferential arrays [34].…”
mentioning
confidence: 99%