2016
DOI: 10.15585/mmwr.mm6540a6
|View full text |Cite
|
Sign up to set email alerts
|

Notes from the Field:Mycobacterium chimaeraContamination of Heater-Cooler Devices Used in Cardiac SurgeryUnited States

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
87
0
4

Year Published

2017
2017
2023
2023

Publication Types

Select...
3
2
2

Relationship

0
7

Authors

Journals

citations
Cited by 108 publications
(94 citation statements)
references
References 3 publications
3
87
0
4
Order By: Relevance
“…Chand et al, sampled 45 HCUs across 12 different UK hospitals and nineteen (42%) were positive for M. chimaera. The results of these and other studies suggest that M. chimaera is a common contaminant of HCUs and that contaminated water within a HCU could be the source of M. chimaera infections 2,3,49,54 .…”
Section: Determining the Source Of Infections Related To Hcusmentioning
confidence: 64%
See 2 more Smart Citations
“…Chand et al, sampled 45 HCUs across 12 different UK hospitals and nineteen (42%) were positive for M. chimaera. The results of these and other studies suggest that M. chimaera is a common contaminant of HCUs and that contaminated water within a HCU could be the source of M. chimaera infections 2,3,49,54 .…”
Section: Determining the Source Of Infections Related To Hcusmentioning
confidence: 64%
“…Of the 261 isolates examined by Chand et al, 94%, including all those from probable cases and 86% of isolates from 3T HCUs clustered very closely (mean pairwise distance of 10 SNPs) 4 . In comparison, a minimum of 2,900 SNPs were detected between any single outbreak isolate and an epidemiologically unlinked isolate 3 . Such data strongly indicate a point source for the contamination of HCUs i.e.…”
Section: Determining the Source Of Infections Related To Hcusmentioning
confidence: 99%
See 1 more Smart Citation
“…[1][2][3] Infections have been publicly reported in five countries, and it has been noted that these infections developed after the Stöckert 3T heating and cooling unit manufactured by Sorin Group Deutschland (now LivaNova) had been used to regulate the body temperature of patients during coronaryartery bypass grafting. [1][2][3][4][5] Infections are presumed to be acquired through airborne transmission of aerosolized bacteria from water tanks. 1 After these reports in the Northern Hemisphere of infections associated with heating and cooling units, health care institutions in Australia and .…”
Section: Mycobacterium Chimaera Spread From Heating and Cooling Unitsmentioning
confidence: 99%
“…3 Various long-standing inflammatory conditions such as autoinflammatory and rheumatic disorders may lead to the deposition of AA amyloid. [3][4][5] Serum amyloid and C-reactive protein are both acute-phase proteins that are often elevated during inflammation. The formation of serum amyloid can be expected in IgG4-related disease, with elevations in C-reactive protein in approximately 40% of patients, 2 although the incidence and magnitude of elevated serum amyloid levels remain unknown.…”
mentioning