1955
DOI: 10.1063/1.3061823
|View full text |Cite
|
Sign up to set email alerts
|

Servomechanisms and Regulating System Design: Vol. II

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

1962
1962
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(8 citation statements)
references
References 0 publications
0
8
0
Order By: Relevance
“…A similar electrical system would be considered to have positive feedback and greater than unity gain. Both systems would oscillate at a frequency-related to the time required for a complete circuit (12,13). By such an analogy C-S respiration would occur whenever the damping factors (FRC, alkaline reserve, short lung-to-brain transit time) are sufficiently compromised.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…A similar electrical system would be considered to have positive feedback and greater than unity gain. Both systems would oscillate at a frequency-related to the time required for a complete circuit (12,13). By such an analogy C-S respiration would occur whenever the damping factors (FRC, alkaline reserve, short lung-to-brain transit time) are sufficiently compromised.…”
Section: Discussionmentioning
confidence: 99%
“…Because of the finite time required for transmission of feedback and the greater than unity gain, the system as described would be unstable at certain frequencies and would result in oscillating fluctuations in ventilatory activity (12,13). Several stabilizing mechanisms operate.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…With reference to Eqn 4, an equation useful for the present purpose is [9] ( ) ( ) (6) An element of viscoelastic material may be considered to be a linear system with input of stress and output of strain or vise versa and the complex modulus is a FRF. By examining Eqn 4, it may be seen that…”
Section: The Basic Fractional Modelmentioning
confidence: 99%
“…The traditional approach to control system design has been to develop the transfer function of the plant, and use such frequency domain techniques as Nyquist or Bode plots, or Nichols charts, [5] to synthesi~e the necessary compensating networks that will ensure the desired response in the time-domain. With the advent of digital computers, interest has returned to the more direct method of working only in the time-domain [6].…”
Section: [24] Simulation Of the Reactormentioning
confidence: 99%