2019
DOI: 10.1088/2053-1591/ab3bba
|View full text |Cite
|
Sign up to set email alerts
|

γ-Fe2O3nanoparticles modified glassy carbon electrode for the sensitive detection of folic acid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
3
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 39 publications
1
3
0
Order By: Relevance
“…The quantitative impedance parameters obtained by fitting using Randles equivalent circuit (Figure 5b, Table 2) show a 17.6-fold decrease of the charge transfer resistance, i.e., improvement of the electron transfer rate for the modified electrode. These data agree with the reported for СеO2 [24] or γ-Fe2O3 [35] NPs, as well as for CeO2/Fe2O3 composite nanospindles [44]. Thus, the effectiveness of the СеO2•Fe2O3 NPs as electrode surface modifier has been confirmed by SEM, EIS, and cyclic voltammetry.…”
Section: Sem and Electrochemical Characterization Of The Electrodessupporting
confidence: 91%
See 1 more Smart Citation
“…The quantitative impedance parameters obtained by fitting using Randles equivalent circuit (Figure 5b, Table 2) show a 17.6-fold decrease of the charge transfer resistance, i.e., improvement of the electron transfer rate for the modified electrode. These data agree with the reported for СеO2 [24] or γ-Fe2O3 [35] NPs, as well as for CeO2/Fe2O3 composite nanospindles [44]. Thus, the effectiveness of the СеO2•Fe2O3 NPs as electrode surface modifier has been confirmed by SEM, EIS, and cyclic voltammetry.…”
Section: Sem and Electrochemical Characterization Of The Electrodessupporting
confidence: 91%
“…are of interest as far as they provide a high effective area of the sensors, high selectivity, and sensitivity of target analyte determination [21,22]. Sensors based on SnO 2, TiO 2 , Fe 2 O 3 , Fe 3 O 4, ZnO, and CeO 2 NPs show sensitive and selective response to natural phenolic antioxidants [23][24][25][26][27][28][29], neuromediators [30][31][32][33], and some pharmaceuticals [34][35][36][37][38]. Electrochemical inertness of this type of NPs is another advantage providing registration of its own redox signal of the target analytes which improves the selectivity of their detection.…”
Section: Linear Dynamicmentioning
confidence: 99%
“…According to the results, the immobilised γ-Fe 2 O 3 NPs on GCE exhibited a very good electro-catalytic activity for the selective and sensitive detection of FA at the physiological pH. With regard to the calibration plot of the peak current against the target analyte concentration, differential pulse stripping voltammetry (DPSV) showed two linear ranges between 0.05 and 1 μM as well as 1 and 80 μM with the LOD of 2.8 and 48 nM [158].…”
Section: Tmo Nps-based Electrochemical Sensors To Analyze the Drug Co...mentioning
confidence: 98%
“…Ramu et al [ 123 ], presented a work demonstrating the use of starch in a different way, which aims to obtain nanoparticles of γ-Fe 2 O 3 (maghemite) with starch aid to modify a CGE. The electrochemical sensor was used in the determination of folic acid in pharmaceutical samples.…”
Section: Starch In Electrochemical Sensors and Biosensorsmentioning
confidence: 99%