1988
DOI: 10.1007/bf00472634
|View full text |Cite
|
Sign up to set email alerts
|

IAEA biological reference materials

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

1990
1990
2024
2024

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 14 publications
(6 citation statements)
references
References 4 publications
0
6
0
Order By: Relevance
“…As shown in Table I, there is generally good agreement between the LC-FL and GC-MS determinations. Differences in the mean values for the two techniques were 1-4% for phenanthrene, anthracene, perylene, and benzo[g/u] perylene; 12% for fluoranthene and pyrene; and 13-15% for benzo[o]pyrene, benzo [5]fluoranthene, and indeno[l,2,3-cd]pyrene. Based on the results from these two techniques, certified concentrations of these nine PAHs were determined and are summarized in Table I.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…As shown in Table I, there is generally good agreement between the LC-FL and GC-MS determinations. Differences in the mean values for the two techniques were 1-4% for phenanthrene, anthracene, perylene, and benzo[g/u] perylene; 12% for fluoranthene and pyrene; and 13-15% for benzo[o]pyrene, benzo [5]fluoranthene, and indeno[l,2,3-cd]pyrene. Based on the results from these two techniques, certified concentrations of these nine PAHs were determined and are summarized in Table I.…”
Section: Resultsmentioning
confidence: 99%
“…Several of the PCB congeners listed in Table III coelute with each other in the commonly used GC-ECD analysis on a DB-5 or similar column (29). For the 13 PCB congeners listed in Table III, 5 congeners may have some contribution from coeluting congeners, e.g., PCB 15 with PCB 18, PCB 95 with PCB 66, PCB 90 with PCB 101, PCB 164 and PCB 163 with PCB 138, and PCB 159 and PCB 182 with PCB 187 (see Figure 2). The extent of the contribution of the coeluting congeners has been shown to vary in marine samples (31).…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…In addition to significant advancement in nail analysis, an improved quality assurance, which is essential, depends on employment of proper certified reference materials (CRM) and participation in the interlaboratory quality control programme (M' Baku and Parr 1982;Parr et al 1988). Currently, the reference material for toenails is available from National Institute of Standard and Technology (USA) and can be used to ensure the validity of adopted methods.…”
Section: G Quality Controlmentioning
confidence: 99%