2023
DOI: 10.1093/jscr/rjad356
|View full text |Cite
|
Sign up to set email alerts
|

Iatrogenic tracheal laceration due to rigid bronchoscopy treated by endoscopic stent placement: a case report

Nozomu Motono,
Takaki Mizoguchi,
Mashahito Ishikawa
et al.

Abstract: Although rigid bronchoscopy may lead to tracheal injury, the incidence is unknown. A 59-year-old woman diagnosed with clinical stage IV esophageal cancer was scheduled to undergo placement of a silicon Y-stent by rigid bronchoscopy to address tracheal stenosis. When the tumor was cored out by rigid bronchoscopy, perforation of the lower trachea occurred, and a silicon Y-stent was inserted to cover the tracheal fistula. Chest X-ray revealed right pneumothorax, and chest drainage was performed. When spontaneous … Show more