1995
DOI: 10.13182/fst95-a30422
|View full text |Cite
|
Sign up to set email alerts
|

ICF Target Technology at the Russian Federal Nuclear Center

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0
1

Year Published

1998
1998
2018
2018

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 12 publications
(6 citation statements)
references
References 4 publications
0
5
0
1
Order By: Relevance
“…According to a recent review on the development of target fabrication for laser-driven ICF at the Research Center of Laser Fusion (RCLF) in China [ 121 ], glow discharge polymer (GDP), glass, and polystyrene (PS) hollow microspheres are among the candidates for the ultimate ignition. Let us just refer to the first type: GDP microballoons can be produced by inductive coupled plasma enhanced chemical vapor deposition (ICP-CVD), a method that permits the deposition of high quality dielectric films at low temperature with low damage.…”
Section: Applications In the Field Of Energymentioning
confidence: 99%
“…According to a recent review on the development of target fabrication for laser-driven ICF at the Research Center of Laser Fusion (RCLF) in China [ 121 ], glow discharge polymer (GDP), glass, and polystyrene (PS) hollow microspheres are among the candidates for the ultimate ignition. Let us just refer to the first type: GDP microballoons can be produced by inductive coupled plasma enhanced chemical vapor deposition (ICP-CVD), a method that permits the deposition of high quality dielectric films at low temperature with low damage.…”
Section: Applications In the Field Of Energymentioning
confidence: 99%
“…Мишень для непрямого облучения состоит из оболочки -конвертера излучения (полая сфера или цилиндр из материала с высоким Z) и сферического топливного ядра, расположенного внутри конверте-ра [15,[48][49][50][51][52][53][54].…”
Section: структура топливной мишени для различных схем итсunclassified
“…We associated the microemulsion enclosure method and microfluidic technology, then designed a double T-junction structure microchannel device based on microfluidic technology [32][33][34], which was used to prepare the hollow microcapsules. Compared to the other types of devices, the double T-junction microfluidic device removes the fussy requirements of hydrophilic and hydrophobic modification to produce double emulsion droplets, which enhance the simplicity and operability of the experiment.…”
Section: Introductionmentioning
confidence: 99%