2006
DOI: 10.1016/j.jpba.2005.07.034
|View full text |Cite
|
Sign up to set email alerts
|

Identification and determination of nucleosides in Cordyceps sinensis and its substitutes by high performance liquid chromatography with mass spectrometric detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

4
40
0

Year Published

2006
2006
2021
2021

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 58 publications
(44 citation statements)
references
References 14 publications
4
40
0
Order By: Relevance
“…The detection limits were 12.6 ng/mL (adenosine), 16.0 ng/mL (cordycepin), 15.1 ng/mL (2′-deoxyadenosine), 9.5 ng/mL (guanosine), 6.5 ng/mL (hypoxanthine) and 9.7 ng/mL (uridine) at a signal-to-noise ratio of 3. The sensitivity of the proposed method for nucleic acid-related compounds was higher than that of CE-UV detection (Li et al, 2002;Gong et al, 2004) and LC-MS detection (Guo et al, 2006;Huang et al, 2003). However, HPLC-MS/MS detection (Fan et al, 2006) was approximately 10-fold more sensitive than the present method.…”
Section: Methods Validationmentioning
confidence: 61%
See 3 more Smart Citations
“…The detection limits were 12.6 ng/mL (adenosine), 16.0 ng/mL (cordycepin), 15.1 ng/mL (2′-deoxyadenosine), 9.5 ng/mL (guanosine), 6.5 ng/mL (hypoxanthine) and 9.7 ng/mL (uridine) at a signal-to-noise ratio of 3. The sensitivity of the proposed method for nucleic acid-related compounds was higher than that of CE-UV detection (Li et al, 2002;Gong et al, 2004) and LC-MS detection (Guo et al, 2006;Huang et al, 2003). However, HPLC-MS/MS detection (Fan et al, 2006) was approximately 10-fold more sensitive than the present method.…”
Section: Methods Validationmentioning
confidence: 61%
“…Therefore, it is necessary to determine further natural CS samples to certificate the contents of nucleic acid-related compounds. Recently, cordycepin in natural CS was found at a very low content by LC-MS (Guo et al, 2006) and HPLC-UV (Li et al, 2002) methods. However, the sensitivity of the latter method was not enough to determine such low contents of cordycepin.…”
Section: Contents Of Nucleosides In Cordycepsmentioning
confidence: 99%
See 2 more Smart Citations
“…Subsequently, the precisely weighed powder (1.0 g) was mixed with approximately 20 mL of water, and then extracted ultrasonically for 1 h at room temperature (Guo et al 2006). The extract solution was filtrated through analytical filter paper.…”
Section: Methodsmentioning
confidence: 99%