2021
DOI: 10.1016/j.scitotenv.2021.145073
|View full text |Cite
|
Sign up to set email alerts
|

Identification and quantification of plastic additives using pyrolysis-GC/MS: A review

Abstract: HAL is a multi-disciplinary open access archive for the deposit and dissemination of scientific research documents, whether they are published or not. The documents may come from teaching and research institutions in France or abroad, or from public or private research centers. L'archive ouverte pluridisciplinaire HAL, est destinée au dépôt et à la diffusion de documents scientifiques de niveau recherche, publiés ou non, émanant des établissements d'enseignement et de recherche français ou étrangers, des labor… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
33
0
2

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
2
1

Relationship

0
10

Authors

Journals

citations
Cited by 93 publications
(36 citation statements)
references
References 57 publications
1
33
0
2
Order By: Relevance
“…877 Carbios has announced partnerships including investors, end customers, enzyme producers, and process and plant designers to accelerate commercialization. 878 Cabios has raised over $126 million to develop their technology, 879 and they currently operate a 1.2 kton/year demonstration facility with goals to build a 40 kton/year facility by 2025. 880…”
Section: Biocatalysismentioning
confidence: 99%
“…877 Carbios has announced partnerships including investors, end customers, enzyme producers, and process and plant designers to accelerate commercialization. 878 Cabios has raised over $126 million to develop their technology, 879 and they currently operate a 1.2 kton/year demonstration facility with goals to build a 40 kton/year facility by 2025. 880…”
Section: Biocatalysismentioning
confidence: 99%
“…26 Because the sample mass that can be analyzed is at the mg or μg level, a substantially higher proportion of additive-loaded plastic needs to be present in the sample, indicating that a preconcentration step may be required before analysis. 27 In this case, low μg amounts of additive-loaded plastic need to be added to the pyrolysis-GC/MS sample cup to identify/quantify an additive. This is in the range of the LOD reported to analyze additives in plastic samples using pyrolysis-GC/ MS. 28,29 For sorbed compounds, the challenge is even larger.…”
Section: Resultsmentioning
confidence: 99%
“…858 Carbios has announced partnerships including investors, end customers, enzyme producers, and process and plant designers to accelerate commercialization. 859 Cabios has raised over $126 million to develop their technology, 860 and they currently operate a 1.2 kton/year demonstration facility with goals to build a 40 kton/year facility by 2025. 861…”
Section: Biocatalysismentioning
confidence: 99%